MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2017.03.018

Медицинская библиотека · JACC. Cardiovascular interventions · 2017

1-Year Results in Patients Undergoing Transcatheter Aortic Valve Replacement With Failed Surgical Bioprostheses.

Deeb G Michael, Chetcuti Stanley J, Reardon Michael J, Patel Himanshu J, Grossman P Michael, Schreiber Theodore, Forrest John K, Bajwa Tanvir K, O'Hair Daniel P, Petrossian George, Robinson Newell, Katz Stanley, Hartman Alan, Dauerman Harold L, Schmoker Joseph, Khabbaz Kamal, Watson Daniel R, Yakubov Steven J, Oh Jae K, Li Shuzhen, Kleiman Neal S, Adams David H, Popma Jeffrey J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study evaluated the safety and effectiveness of self-expanding transcatheter aortic valve replacement (TAVR) in patients with surgical valve failure (SVF).

BACKGROUND

Self-expanding TAVR is superior to medical therapy for patients with severe native aortic valve stenosis at increased surgical risk.

METHODS

The CoreValve U.S. Expanded Use Study was a prospective, nonrandomized study that enrolled 233 patients with symptomatic SVF who were deemed unsuitable for reoperation. Patients were treated with self-expanding TAVR and evaluated for 30-day and 1-year outcomes after the procedure. An independent core laboratory was used to evaluate serial echocardiograms for valve hemodynamics and aortic regurgitation.

RESULTS

SVF occurred through stenosis (56.4%), regurgitation (22.0%), or a combination (21.6%). A total of 227 patients underwent attempted TAVR and successful TAVR was achieved in 225 (99.1%) patients. Patients were elderly (76.7 ± 10.8 years), had a Society of Thoracic Surgeons Predicted Risk of Mortality score of 9.0 ± 6.7%, and were severely symptomatic (86.8% New York Heart Association functional class III or IV). The all-cause mortality rate was 2.2% at 30 days and 14.6% at 1 year; major stroke rate was 0.4% at 30 days and 1.8% at 1 year. Moderate aortic regurgitation occurred in 3.5% of patients at 30 days and 7.4% of patients at 1 year, with no severe aortic regurgitation. The rate of new permanent pacemaker implantation was 8.1% at 30 days and 11.0% at 1 year. The mean valve gradient was 17.0 ± 8.8 mm Hg at 30 days and 16.6 ± 8.9 mm Hg at 1 year. Factors significantly associated with higher discharge mean aortic gradients were surgical valve size, stenosis as modality of SVF, and presence of surgical valve prosthesis patient mismatch (all p < 0.001).

CONCLUSIONS

Self-expanding TAVR in patients with SVF at increased risk for surgery was associated with a low 1-year mortality and major stroke rate, significantly improved aortic valve hemodynamics, and low rates of moderate and no severe residual aortic regurgitation, with improved quality of life.

Для цитирования: Deeb G Michael, Chetcuti Stanley J, Reardon Michael J, Patel Himanshu J, Grossman P Michael, Schreiber Theodore, Forrest John K, Bajwa Tanvir K, O'Hair Daniel P, Petrossian George, Robinson Newell, Katz Stanley, Hartman Alan, Dauerman Harold L, Schmoker Joseph, Khabbaz Kamal, Watson Daniel R, Yakubov Steven J, Oh Jae K, Li Shuzhen, Kleiman Neal S, Adams David H, Popma Jeffrey J. 1-Year Results in Patients Undergoing Transcatheter Aortic Valve Replacement With Failed Surgical Bioprostheses.. JACC. Cardiovascular interventions. 2017. DOI: 10.1016/j.jcin.2017.03.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.