MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/ma19183907

Медицинская библиотека · Materials (Basel, Switzerland) · 2026

Effect of Electrolytic-Plasma Hardening Parameters on the Microstructure and Mechanical Behavior of 20X Steel.

Kussainov Arystanbek, Aringozhina Zarina, Zhunissova Gulnara, Bayatanova Lyaila, Rakhadilov Bauyrzhan, Kaliaskarova Moldir

СтатьяПеревод пока не подготовлен

Аннотация

This study investigates the effects of applied voltage and treatment duration during electrolytic-plasma hardening (EPH) on the microstructure, phase composition, hardness, surface condition, and tribological behavior of 20X steel. EPH was performed in a 12 wt.% Na2CO3 aqueous electrolyte at voltages of 280, 300, and 320 V for 4 and 6 s. Scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray diffraction, instrumented indentation, surface profilometry, and ball-on-disk tribological testing were used to characterize the treated specimens. The 280 V/4 s, 300 V/4 s, 320 V/4 s, and 280 V/6 s conditions produced thermally modified surface layers without visible surface damage, whereas treatment at 300 and 320 V for 6 s resulted in localized surface melting. Among the undamaged specimens, the highest hardness was obtained at 280 V, reaching 329.6 ± 15.8 HV after 4 s and 332.1 ± 26.3 HV after 6 s, corresponding to an approximately 1.83-1.85-fold increase relative to the initial value of 180 HV. XRD revealed a predominantly α-Fe-based matrix, while weak secondary reflections could not be assigned reliably to specific phases. The minimum steady-state coefficient of friction was obtained at 300 V/4 s (0.444 ± 0.054), whereas the narrowest wear track was observed at 320 V/4 s (379.48 ± 36.24 μm). No direct correlation was found between hardness and tribological response, indicating that surface roughness and microstructural state should also be considered when selecting treatment parameters. The results define a stable EPH processing window for 20X steel and demonstrate that parameter selection should be based on a combined assessment of surface integrity, hardness, and tribological performance.

Для цитирования: Kussainov Arystanbek, Aringozhina Zarina, Zhunissova Gulnara, Bayatanova Lyaila, Rakhadilov Bauyrzhan, Kaliaskarova Moldir. Effect of Electrolytic-Plasma Hardening Parameters on the Microstructure and Mechanical Behavior of 20X Steel.. Materials (Basel, Switzerland). 2026. DOI: 10.3390/ma19183907.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.