BACKGROUND

Isolated tricuspid valve surgery is associated with high morbidity and mortality, especially in patients with prior cardiac surgery. The transcatheter Forma Repair System (Edwards Lifesciences, Irvine, California) is designed to provide a surface for native leaflet coaptation to reduce tricuspid regurgitation (TR) by occupying the regurgitant orifice area.

OBJECTIVES

This study sought to evaluate the feasibility and exploratory efficacy with this transcatheter repair system for the treatment of severe TR.

METHODS

Seven high-risk patients with severe TR and clinical signs of heart failure were declined for surgery and offered transcatheter treatment with this device. All procedures were performed within a cardiac catheterization laboratory or hybrid operating room under general anesthesia with transesophageal echocardiographic guidance. Vascular access was via the left axillary vein. Baseline characteristics, procedural and in-hospital outcomes, as well as 30-day follow-up were prospectively collected.

RESULTS

All patients had severe TR and New York Heart Association (NYHA) functional class II to IV (mean age 76 ± 13 years; mean logistic EuroSCORE 25.7 ± 17.4%), and underwent device implantation to improve tricuspid leaflet coaptation, thereby reducing TR. Device implantation was successful without procedural complications in all patients, with significant reductions in TR severity (moderate in 3 patients and mild in 4 patients). Median hospital length of stay was 4 days. At 30-day follow-up, all patients but 1 demonstrated improvements in NYHA functional status (to class II) with pronounced reductions in the presence and severity of peripheral edema. TR severity was assessed as being moderate at 30-day transthoracic echocardiography follow-up in all patients. No complications related to the device or vascular access were observed during follow-up.

CONCLUSIONS

A transcatheter-based treatment option for severe TR appears safe and feasible with this repair system. Improvements in TR severity were documented in all patients, which were accompanied by improvements in peripheral edema and functional status.

Для цитирования: Campelo-Parada Francisco, Perlman Gidon, Philippon François, Ye Jian, Thompson Christopher, Bédard Elisabeth, Abdul-Jawad Altisent Omar, Del Trigo Maria, Leipsic Jonathon, Blanke Philipp, Dvir Danny, Puri Rishi, Webb John G, Rodés-Cabau Josep. First-in-Man Experience of a Novel Transcatheter Repair System for Treating Severe Tricuspid Regurgitation.. Journal of the American College of Cardiology. 2015. DOI: 10.1016/j.jacc.2015.09.068.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.