MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2015.05.010

Медицинская библиотека · JACC. Cardiovascular interventions · 2015

Inverse Relationship Between Membranous Septal Length and the Risk of Atrioventricular Block in Patients Undergoing Transcatheter Aortic Valve Implantation.

Hamdan Ashraf, Guetta Victor, Klempfner Robert, Konen Eli, Raanani Ehud, Glikson Michael, Goitein Orly, Segev Amit, Barbash Israel, Fefer Paul, Spiegelstein Dan, Goldenberg Ilan, Schwammenthal Ehud

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study sought to examine whether imaging of the atrioventricular (AV) membranous septum (MS) by computed tomography (CT) can be used to identify patient-specific anatomic risk of high-degree AV block and permanent pacemaker (PPM) implantation before transcatheter aortic valve implantation (TAVI) with self-expandable valves.

BACKGROUND

MS length represents an anatomic surrogate of the distance between the aortic annulus and the bundle of His and may therefore be inversely related to the risk of conduction system abnormalities after TAVI.

METHODS

Seventy-three consecutive patients with severe aortic stenosis underwent contrast-enhanced CT before TAVI. The aortic annulus, aortic valve, and AV junction were assessed, and MS length was measured in the coronal view.

RESULTS

In 13 patients (18%), high-degree AV block developed, and 21 patients (29%) received a PPM. Multivariable logistic regression analysis revealed MS length as the most powerful pre-procedural independent predictor of high-degree AV block (odds ratio [OR]: 1.35, 95% confidence interval [CI]: 1.1 to 1.7, p = 0.01) and PPM implantation (OR: 1.43, 95% CI: 1.1 to 1.8, p = 0.002). When taking into account pre- and post-procedural parameters, the difference between MS length and implantation depth emerged as the most powerful independent predictor of high-degree AV block (OR: 1.4, 95% CI: 1.2 to 1.7, p < 0.001), whereas the difference between MS length and implantation depth and calcification in the basal septum were the most powerful independent predictors of PPM implantation (OR: 1.39, 95% CI: 1.2 to 1.7, p < 0.001 and OR: 4.9, 95% CI: 1.2 to 20.5, p = 0.03; respectively).

CONCLUSIONS

Short MS, insufficient difference between MS length and implantation depth, and the presence of calcification in the basal septum, factors that may all facilitate mechanical compression of the conduction tissue by the implanted valve, predict conduction abnormalities after TAVI with self-expandable valves. CT assessment of membranous septal anatomy provides unique pre-procedural information about the patient-specific propensity for the risk of AV block.

Для цитирования: Hamdan Ashraf, Guetta Victor, Klempfner Robert, Konen Eli, Raanani Ehud, Glikson Michael, Goitein Orly, Segev Amit, Barbash Israel, Fefer Paul, Spiegelstein Dan, Goldenberg Ilan, Schwammenthal Ehud. Inverse Relationship Between Membranous Septal Length and the Risk of Atrioventricular Block in Patients Undergoing Transcatheter Aortic Valve Implantation.. JACC. Cardiovascular interventions. 2015. DOI: 10.1016/j.jcin.2015.05.010.