MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2015.07.014

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2015

Biomechanical drawbacks of different techniques of mitral neochordal implantation: When an apparently optimal repair can fail.

Sturla Francesco, Votta Emiliano, Onorati Francesco, Pechlivanidis Konstantinos, Pappalardo Omar A, Gottin Leonardo, Milano Aldo D, Puppini Giovanni, Redaelli Alberto, Faggian Giuseppe

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Intraoperative assessment of the proper neochordal length during mitral plasty may be complex sometimes. Patient-specific finite element models were used to elucidate the biomechanical drawbacks underlying an apparently correct mitral repair for isolated posterior prolapse.

METHODS

Preoperative patient-specific models were derived from cardiac magnetic resonance images; integrated with intraoperative surgical details to assess the location and extent of the prolapsing region, including the number and type of diseased chordae; and complemented by the biomechanical properties of mitral leaflets, chordae tendineae, and artificial neochordae. We investigated postoperative mitral valve biomechanics in a wide spectrum of different techniques (single neochorda, double neochordae, and preconfigured neochordal loop), all reestablishing adequate valvular competence, but differing in suboptimal millimetric expanded polytetrafluoroethylene suture lengths in a range of ±2 mm, compared with the corresponding "ideal repair."

RESULTS

Despite the absence of residual regurgitation, alterations in chordal forces and leaflet stresses arose simulating suboptimal repairs; alterations were increasingly relevant as more complex prolapse anatomies were considered and were worst when simulating single neochorda implantation. Multiple chordae implantations were less sensitive to errors in neochordal length tuning, but associated postoperative biomechanics were hampered when asymmetric configurations were reproduced. Computational outcomes were consistent with the presence and entity of recurrent mitral regurgitation at midterm follow-up of simulated patients.

CONCLUSIONS

Suboptimal suture length tuning significantly alters chordal forces and leaflet stresses, which may be key parameters in determining the long-term outcome of the repair. The comparison of the different simulated techniques suggests possible criteria for the selection and implementation of neochordae implantation techniques.

Для цитирования: Sturla Francesco, Votta Emiliano, Onorati Francesco, Pechlivanidis Konstantinos, Pappalardo Omar A, Gottin Leonardo, Milano Aldo D, Puppini Giovanni, Redaelli Alberto, Faggian Giuseppe. Biomechanical drawbacks of different techniques of mitral neochordal implantation: When an apparently optimal repair can fail.. The Journal of thoracic and cardiovascular surgery. 2015. DOI: 10.1016/j.jtcvs.2015.07.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.