DOI 10.1016/j.compmedimag.2014.09.005

Медицинская библиотека · Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society · 2014

A simple and accurate method for computer-aided transapical aortic valve replacement.

Karar Mohamed Esmail, Merk Denis R, Falk Volkmar, Burgert Oliver

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Transapical aortic valve replacement (TAVR) is a recent minimally invasive surgical treatment technique for elderly and high-risk patients with severe aortic stenosis. In this paper, a simple and accurate image-based method is introduced to aid the intra-operative guidance of TAVR procedure under 2-D X-ray fluoroscopy.

METHODS

The proposed method fuses a 3-D aortic mesh model and anatomical valve landmarks with live 2-D fluoroscopic images. The 3-D aortic mesh model and landmarks are reconstructed from interventional X-ray C-arm CT system, and a target area for valve implantation is automatically estimated using these aortic mesh models. Based on template-based tracking approach, the overlay of visualized 3-D aortic mesh model, landmarks and target area of implantation is updated onto fluoroscopic images by approximating the aortic root motion from a pigtail catheter motion without contrast agent. Also, a rigid intensity-based registration algorithm is used to track continuously the aortic root motion in the presence of contrast agent. Furthermore, a sensorless tracking of the aortic valve prosthesis is provided to guide the physician to perform the appropriate placement of prosthesis into the estimated target area of implantation.

RESULTS

Retrospective experiments were carried out on fifteen patient datasets from the clinical routine of the TAVR. The maximum displacement errors were less than 2.0mm for both the dynamic overlay of aortic mesh models and image-based tracking of the prosthesis, and within the clinically accepted ranges. Moreover, high success rates of the proposed method were obtained above 91.0% for all tested patient datasets.

CONCLUSION

The results showed that the proposed method for computer-aided TAVR is potentially a helpful tool for physicians by automatically defining the accurate placement position of the prosthesis during the surgical procedure.

Для цитирования: Karar Mohamed Esmail, Merk Denis R, Falk Volkmar, Burgert Oliver. A simple and accurate method for computer-aided transapical aortic valve replacement.. Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society. 2014. DOI: 10.1016/j.compmedimag.2014.09.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.