[Usefulness of echocardiography for detecting prosthetic valve dysfunction; report of a case].

Oyama Shogo, Ohuchi Shingo, Okubo Tadashi, Kumagai Kazuya

Клинический случайАннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

A 78-year-old woman with a history of mitral valve stenosis underwent open mitral commissurotomy in 1976. In 1990, she underwent mitral valve replacement (Medtronic-Hall 29 mm), tricuspid annuloplasty(DeVega method), and pacemaker implantation for bradycardiac atrial fibrillation. However, in June 2012, she developed anemia of unknown cause. Prosthetic valve dysfunction was suspected, because intermittent changes in the left ventricular inflow was detected by echocardiography. Fluoroscopy actually confirmed the presence of prosthetic valve dysfunction. Therefore mitral valve re-replacement(ATS Medical, Inc. 29 mm) and tricuspid annuloplasty (Cosgrove ring 30 mm) were performed. Monitoring the changes in the left ventricular inflow is recommended when prosthetic valve dysfunction in a single leaflet is suspected.

Для цитирования: Oyama Shogo, Ohuchi Shingo, Okubo Tadashi, Kumagai Kazuya. [Usefulness of echocardiography for detecting prosthetic valve dysfunction; report of a case].. Kyobu geka. The Japanese journal of thoracic surgery. 2014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.