DOI 10.3389/fphar.2025.1516339
Therapeutic vancomycin monitoring: a comparative analysis of high-performance liquid chromatography and chemiluminescent microparticle immunoassay methods in liver transplant recipients.
Аннотация
BACKGROUND
Vancomycin is a glycopeptide antibiotic of choice for treating serious Gram-positive bacterial infections, including methicillin-resistant Staphylococcus aureus (MRSA). However, its therapeutic efficacy and risk of nephrotoxicity are closely related to maintaining specific serum concentration levels. Liver transplant recipients (LTRs) require precise therapeutic drug monitoring (TDM) due to altered pharmacokinetics. This study compares the accuracy and precision of two vancomycin measurement methods-chemiluminescent microparticle immunoassay (CMIA) and high-performance liquid chromatography (HPLC) in LTRs.
METHODS
The cross-sectional study was conducted over 11 months at the Abu-Ali Sina Solid Organ Transplant Hospital in Shiraz, Iran. The study included 34 adult LTRs on vancomycin treatment, excluding those with hypersensitivity, chronic kidney disease, burn injuries, or receiving phenytoin. Blood samples were collected at different intervals post-vancomycin administration and analyzed using both CMIA and HPLC methods.
RESULTS
HPLC demonstrated superior accuracy and precision in measuring vancomycin concentrations, particularly in identifying patients with vancomycin-induced nephrotoxicity. Significantly higher trough (p-value: 0.026) and intermediate (p-value: 0.49) concentrations were detected by HPLC in patients experiencing nephrotoxicity, whereas CMIA did not show significant differences between groups. Pharmacokinetic variables such as half-life (p-value: 0.024) and AUC (p-value:0.037), measured by HPLC, were significantly different between LTRs with and without nephrotoxicity, which was not observed with CMIA.
CONCLUSION
HPLC is more sensitive and reliable than CMIA for measuring vancomycin levels in LTRs, which is critical for optimizing vancomycin therapy and preventing adverse effects. The research suggests that HPLC should be the preferred method for vancomycin TDM in LTRs and further multicenter studies are recommended to validate these results.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.