Annular Reduction by Cinching With TEER in Commissure in Conventionally Inappropriate Ring for Transcatheter Valve.

Chidester Jeffrey, Yarboro Leora, McCabe James, Saxon John

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Annular reduction by cinching with transcatheter edge-to-edge repair in commissure has been described to enable valve-in-mitral annular calcification. We applied this technique to a patient with an annuloplasty ring too large to allow for treatment with available transcatheter heart valves.

KEY STEPS: The key steps included the following: Gated computed tomography for measurement of annuloplasty ring, anterior mitral leaflet, and estimated neo-left ventricular outflow tract (LVOT). Transseptal left atrial access is obtained. Mitral transcatheter edge to edge repair (MTEER) is performed with preference for A3-P3 implant. Adjunctive antegrade base-to-tip laceration of the anterior mitral valve leaflet to prevent LVOT obstruction is performed if indicated. Transcatheter heart valve (THV) delivery and deployment.

POTENTIAL PITFALLS: The potential pitfalls included the following: Medial deployment of the MTEER device is preferred due to the tendency of the THV to engage the lateral mitral anulus during advancement. Assessment of the neo-LVOT must consider the left ventricular septum and the anterior mitral leaflet. The degree of annular change after MTEER is unknown.

TAKE-HOME MESSAGE: In the setting of a mitral annuloplasty ring larger than commercially available THVs, annular reduction by cinching with TEER in commissure in conventionally inappropriate ring for transcatheter valve may be a viable option for enabling transcatheter mitral valve replacement.

Для цитирования: Chidester Jeffrey, Yarboro Leora, McCabe James, Saxon John. Annular Reduction by Cinching With TEER in Commissure in Conventionally Inappropriate Ring for Transcatheter Valve.. JACC. Case reports. 2025. DOI: 10.1016/j.jaccas.2025.105366.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.