Ultrasound-guided subscalene approach for the brachial plexus in dogs: a descriptive cadaveric study.

Fuensalida Santiago E, Tarragona Lisa, Díaz Alfredo, Giansanti Nicolas H, Briganti Angela, Portela Diego A, Otero Pablo E

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To describe the ultrasound anatomy of the subscalene groove, evaluate the feasibility of an in-plane subscalene approach to the brachial plexus (BP) and compare one- and two-point injection techniques for BP staining in canine cadavers.

STUDY

DESIGN

Prospective, randomized, descriptive anatomical study.

ANIMALS: Nineteen thawed male and female adult canine cadavers [mass 3-40 kg, body condition scores 4-6/9 (range)].

METHODS

Ultrasonography and anatomical dissections were performed in two cadavers to study the relationship between cervical muscles and the ventral branches of the last three cervical spinal nerves (C6, C7, C8) and the first thoracic spinal nerve (T1). Seventeen thawed cadavers were then used to assess nerve staining following ultrasound-guided subscalene injections. Group 1 dogs (G1, n = 17) were injected with 0.4 mL kg-1 of dye cranial to C8 in the subscalene groove using a single injection point. Group 2 dogs (G2, n = 17) were injected with dye in the same intermuscular plane, split into two injections: 0.3 mL kg-1 cranial to C8 and 0.1 mL kg-1 cranial to C7 on the contralateral side. Staining was considered successful if C6, C7, C8 and T1 were stained circumferentially (>1 cm) and unsuccessful if any branch was unstained. Outcomes were analyzed using Fisher's exact test, with significance set at p < 0.05.

RESULTS

Sonoanatomy matched anatomical dissections, with target nerves identified in all cadavers. Staining success rates were 41% in G1 and 88% in G2 (p = 0.0104). Median (range) stained ventral branches were 3 (2-4) in G1 and 4 (3-4) in G2.

CONCLUSIONS AND CLINICAL RELEVANCE: The ultrasound-guided subscalene approach facilitated reliable identification of the BP at the subscalene groove. Successful staining of all target nerves required two injection aliquots. Future clinical studies are warranted to assess the applicability and efficacy of this technique in live animals.

Для цитирования: Fuensalida Santiago E, Tarragona Lisa, Díaz Alfredo, Giansanti Nicolas H, Briganti Angela, Portela Diego A, Otero Pablo E. Ultrasound-guided subscalene approach for the brachial plexus in dogs: a descriptive cadaveric study.. Veterinary anaesthesia and analgesia. 2025. DOI: 10.1016/j.vaa.2025.04.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.