MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s25051507

Медицинская библиотека · Sensors (Basel, Switzerland) · 2025

Pressure Sensors for Measuring Tibiofemoral Contact Mechanics in Meniscal Root Repair: A Systematic Review.

Boksh Khalis, Bashabayev Beibit, Shepherd Duncan E T, Espino Daniel M, Ghosh Arijit, Aujla Randeep, Boutefnouchet Tarek

СтатьяСистематический обзорПеревод пока не подготовлен

Аннотация

BACKGROUND

Tibiofemoral contact mechanics (TFCM) is an accepted biomechanical metrics for evaluating the meniscus in its intact, torn, and repaired states. Pressure sensors are increasingly used, with accuracy and repeatability influenced by test conditions, their design, and their properties. To identify factors optimising performance, we performed a systematic review of the literature on their use for measuring TFCM in posterior meniscal root tears.

METHODS

The Cochrane Controlled Register of Trials, PubMed, and Embase were used to perform a systematic review using the PRISMA criteria. As laboratory and surgical setup can influence sensor performance, we collected data on specimen preparation, repair techniques, hardware use, and biomechanical testing parameters.

RESULTS

24 biomechanical studies were included. Specimen preparations were similar across studies with respect to femoral and tibial mounting. Single axial compressive forces were applied between 100 and 1800 N at varying flexion angles (0-90°). Tekscan (Boston, MA, USA) was the commonest sensor used to measure TFCM, followed by digital capacitive sensors and Fujifilm (Tokyo, Japan). Factors influencing their performance included fluid exposure, lack of adequate fixation, non-specific calibration protocols, load saturation exceeding calibration, damaged sensels and inappropriate pre-test conditioning.

CONCLUSIONS

Understanding potential factors influencing pressure sensors may improve accuracy, area, and pressure distribution measurements.

Для цитирования: Boksh Khalis, Bashabayev Beibit, Shepherd Duncan E T, Espino Daniel M, Ghosh Arijit, Aujla Randeep, Boutefnouchet Tarek. Pressure Sensors for Measuring Tibiofemoral Contact Mechanics in Meniscal Root Repair: A Systematic Review.. Sensors (Basel, Switzerland). 2025. DOI: 10.3390/s25051507.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.