Analysis of Antibody Markers as Immune Correlates of Risk of Severe COVID-19 in the PREVENT-19 Efficacy Trial of the NVX-CoV2373 Recombinant Protein Vaccine.

Fong Youyi, Huang Yunda, Huang Ying, Woo Wayne, McGarry Alice, Áñez Germán, Dunkle Lisa M, Cho Iksung, Houchens Christopher R, Martins Karen, Jayashankar Lakshmi, Castellino Flora, Petropoulos Christos J, Leith Andrew, Haugaard Deanne, Webb William, Lu Yiwen, Yu Chenchen, Carpp Lindsay N, Randhawa April K, Andrasik Michele P, Kublin James G, Hutter Julia, Keshtkar-Jahromi Maryam, Beresnev Tatiana H, Rodriguez Carina A, Tapia Milagritos, Turley Christine B, Zorrilla Carmen D, Cohen Stuart H, Kline Susan E, Barranco Elizabeth, Corey Lawrence, Neuzil Kathleen M, Follmann Dean, Ake Julie A, Gay Cynthia L, Kotloff Karen L, Jones Thomas, Koup Richard A, Donis Ruben O, Gilbert Peter B

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПоддержка правительства СШАResearch Support, N.I.H., IntramuralПеревод в очереди

Аннотация

BACKGROUND

We previously showed that ancestral-specific anti-Spike binding IgG concentration and 50% inhibitory dilution neutralizing antibody titer (nAb-ID50) measured at 2 weeks postdose 2 (∼peak) were inverse correlates of risk (CoRs) of COVID-19 over 2 months post ∼peak in the PREVENT-19 trial of the NVX-CoV2373 vaccine; there were not sufficient data to assess CoRs of severe COVID-19.

METHODS

Here, we assessed, in the same vaccinated cohort, Delta- and ancestral-specific Spike IgG and nAb-ID50 at ∼peak and over time as CoRs of severe COVID-19 and of Delta COVID-19 over 3.5-10 months post ∼peak (287 breakthrough Delta cases, including 8 severe; 446 noncases).

RESULTS

Peak antibody levels were much higher for noncases versus severe cases (all inferred Delta), with nAb-ID50 Delta geometric mean 209.5 arbitrary units (AU)/mL (95% CI: 176.1, 249.1) versus 9.6 AU/mL (95% CI: 2.4, 38.6), respectively. Frequency of detectable nAb-ID50 titer was 98.3% (97.2, 99.0) for noncases versus 62.5% (22.3, 93.9) for severe cases. All markers were inverse CoRs of severe COVID-19, with a ∼peak hazard ratio (HR) of 0.13 (95% CI: .03, .57) per 10-fold nAb-ID50 Delta increase. Severe COVID-19 risk through 305 days postday 35 was 0.0338 (0.0043, 0.206) at the nAb-ID50 Delta 2.5th percentile (8.4 AU/mL), and 0.002 (0.0000, 0.0108) and 0.0002 (0.0000, 0.0035) at the 50th and 95th percentiles (210, 2522 AU/mL).

CONCLUSIONS

Postvaccination NVX-CoV2373 antibody levels are stronger predictors of severe COVID-19 than any-severity Delta COVID-19. Low antibody responses indicate vulnerability to severe COVID-19.

Для цитирования: Fong Youyi, Huang Yunda, Huang Ying, Woo Wayne, McGarry Alice, Áñez Germán, Dunkle Lisa M, Cho Iksung, Houchens Christopher R, Martins Karen, Jayashankar Lakshmi, Castellino Flora, Petropoulos Christos J, Leith Andrew, Haugaard Deanne, Webb William, Lu Yiwen, Yu Chenchen, Carpp Lindsay N, Randhawa April K, Andrasik Michele P, Kublin James G, Hutter Julia, Keshtkar-Jahromi Maryam, Beresnev Tatiana H, Rodriguez Carina A, Tapia Milagritos, Turley Christine B, Zorrilla Carmen D, Cohen Stuart H, Kline Susan E, Barranco Elizabeth, Corey Lawrence, Neuzil Kathleen M, Follmann Dean, Ake Julie A, Gay Cynthia L, Kotloff Karen L, Jones Thomas, Koup Richard A, Donis Ruben O, Gilbert Peter B. Analysis of Antibody Markers as Immune Correlates of Risk of Severe COVID-19 in the PREVENT-19 Efficacy Trial of the NVX-CoV2373 Recombinant Protein Vaccine.. Clinical infectious diseases : an official publication of the Infectious Diseases Society of America. 2026. DOI: 10.1093/cid/ciaf558.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.