MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/hel.70012

Медицинская библиотека · Helicobacter · 2025

The Accuracy of Melting Curve-Based Multiplex Real-Time PCR for Diagnosing Helicobacter pylori Resistance to Clarithromycin and Levofloxacin in Stool Specimens.

Wang Youhua, Gong Xiaoling, Lai Qirui, Fang Hui, Yang Xiyin, Li Xuan, Liu Dong Sheng, Xie Yong

СтатьяОценочное исследованиеПеревод пока не подготовлен

Аннотация

AIMS: This study evaluates the accuracy of melting curve-based multiplex real-time PCR (multiplex rt-PCR) on stool samples for diagnosing antibiotic resistance in Helicobacter pylori (H. pylori) compared to E-test and sequencing.

METHODS

Gastric biopsies and stool samples were collected from 385 H. pylori-infected patients. A total of 325 strains were isolated, and genomic DNA was extracted from all 385 stool samples. E-tests were conducted to detect phenotypic resistance for clarithromycin and levofloxacin. Sanger sequencing and multiplex rt-PCR were employed to identify H. pylori 23S rRNA and GyrA mutations.

RESULTS

E-test results indicated that 203 (62.5%) were susceptible to both clarithromycin and levofloxacin, 33 (10.2%) exhibited mono-resistance to clarithromycin, 48 (14.8%) showed mono-resistance to levofloxacin, and 41 (12.6%) had dual resistance to both antibiotics. Compared to E-test results, the sensitivity and specificity of the multiplex rt-PCR method for detecting clarithromycin resistance mutation were 93.2 (95% CI 84.3-97.5) and 87.1% (95% CI 82.2-90.9), respectively. For levofloxacin resistance mutation, the multiplex rt-PCR method showed a sensitivity of 80.7 (95% CI 70.3-88.3) and a specificity of 93.0% (95% CI 88.7-95.8). Compared to Sanger sequencing, the sensitivity and specificity of the multiplex rt-PCR method for detecting clarithromycin resistance mutation were 95.8 (95% CI 90.0-98.4) and 96.0% (95% CI 92.6-98.0), respectively. For levofloxacin resistance mutation, the multiplex rt-PCR method showed a sensitivity of 91.3% (95% CI, 83.1-95.9) and a specificity of 96.1% (95% CI, 92.7-98.0).

CONCLUSION

Genotypic methods, including Sanger sequencing and multiplex rt-PCR, were rapid and reliable for diagnosing clarithromycin and levofloxacin resistance in the stool samples.

Для цитирования: Wang Youhua, Gong Xiaoling, Lai Qirui, Fang Hui, Yang Xiyin, Li Xuan, Liu Dong Sheng, Xie Yong. The Accuracy of Melting Curve-Based Multiplex Real-Time PCR for Diagnosing Helicobacter pylori Resistance to Clarithromycin and Levofloxacin in Stool Specimens.. Helicobacter. 2025. DOI: 10.1111/hel.70012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.