MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Investigative ophthalmology & visual science · 1996

Directed migration of corneal epithelial sheets in physiological electric fields.

Zhao M, Agius-Fernandez A, Forrester J V, McCaig C D

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To characterize the effects of small applied electric fields (EFs) (100 to 250 mV/ mm) on cultured bovine corneal epithelial cell (CEC) sheets and to determine how EFs interact with other environmental cues in directing CEC sheet migration.

METHODS

Primary cultures of bovine CECs were exposed to EFs in medium with or without serum, epithelial growth factor, basic fibroblast growth factor, or transforming growth factor-beta 1. Cell sheet migration was traced using an image analyzer.

RESULTS

Cell sheets migrated toward the cathode (negative pole). The directional migration was voltage dependent, and, at low field strength (up to 200 mV/mm), it required serum in the medium. Sheets showed no migration responses up to 200 mV/mm in serum-free medium, whereas those in medium with serum showed evident migration toward the cathode, at an average rate of approximately 15 microns/h (n = 15 approximately 20) at 150 mV/mm. When serum was present, the threshold was below 100 mV/mm, very close to the measured wound field strength (approximately 42 mV/mm). After supplementing serum-free medium with individual growth factors or with combinations of epithelial growth factor, basic fibroblast growth factor, and transforming growth factor-beta 1, significant restoration of cathode-directed migration occurred at 150 mV/ mm. Lamellipodia were abundant at the leading edges of migrating sheets, extending the area of sheets covered. The extension of cell membranes toward the cathode was more prominent in cell sheets than in single cells.

CONCLUSIONS

The endogenous EFs generated by wounded cornea could play an important role by interacting with other environmental factors to promote changes in shape and in directed migration of CEC sheets.

Для цитирования: Zhao M, Agius-Fernandez A, Forrester J V, McCaig C D. Directed migration of corneal epithelial sheets in physiological electric fields.. Investigative ophthalmology & visual science. 1996.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.