MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/infdis/jiae226

Медицинская библиотека · The Journal of infectious diseases · 2024

Validation of an Automated, End-to-End Metagenomic Sequencing Assay for Agnostic Detection of Respiratory Viruses.

Gauthier Nick P G, Chan Wilson, Locher Kerstin, Smailus Duane, Coope Robin, Charles Marthe, Jassem Agatha, Kopetzky Jennifer, Chorlton Samuel D, Manges Amee R

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Current molecular diagnostics are limited in the number and type of detectable pathogens. Metagenomic next-generation sequencing (mNGS) is an emerging, and increasingly feasible, pathogen-agnostic diagnostic approach. Translational barriers prohibit the widespread adoption of this technology in clinical laboratories. We validate an end-to-end mNGS assay for detection of respiratory viruses. Our assay is optimized to reduce turnaround time, lower cost per sample, increase throughput, and deploy secure and actionable bioinformatic results.

METHODS

We validated our assay using residual nasopharyngeal swab specimens from Vancouver General Hospital (n = 359), which were reverse-transcription polymerase chain reaction positive, or negative for influenza, severe acute respiratory syndrome coronavirus 2, and respiratory syncytial virus. We quantified sample stability, assay precision, the effect of background nucleic acid levels, and analytical limits of detection. Diagnostic performance metrics were estimated.

RESULTS

We report that our mNGS assay is highly precise and semiquantitative, with analytical limits of detection ranging from 103 to 104 copies/mL. Our assay is highly specific (100%) and sensitive (61.9% overall: 86.8%; reverse-transcription polymerase chain reaction cycle threshold < 30). Multiplexing capabilities enable processing of up to 55 specimens simultaneously on an Oxford Nanopore GridION device, with results reported within 12 hours.

CONCLUSIONS

This study report outlines the diagnostic performance and feasibility of mNGS for respiratory viral diagnostics, infection control, and public health surveillance. We addressed translational barriers to widespread mNGS adoption.

Для цитирования: Gauthier Nick P G, Chan Wilson, Locher Kerstin, Smailus Duane, Coope Robin, Charles Marthe, Jassem Agatha, Kopetzky Jennifer, Chorlton Samuel D, Manges Amee R. Validation of an Automated, End-to-End Metagenomic Sequencing Assay for Agnostic Detection of Respiratory Viruses.. The Journal of infectious diseases. 2024. DOI: 10.1093/infdis/jiae226.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.