MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ccm.0000000000005558

Медицинская библиотека · Critical care medicine · 2022

The Feasibility of Implementing Targeted SEDation in Mechanically Ventilated Emergency Department Patients: The ED-SED Pilot Trial.

Fuller Brian M, Roberts Brian W, Mohr Nicholas M, Faine Brett, Drewry Anne M, Wessman Brian T, Ablordeppey Enyo, Pappal Ryan D, Stephens Robert J, Sewatsky Thomas, Cho Nicholas S, Yan Yan, Kollef Marin H, Carpenter Christopher R, Avidan Michael S

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Deep sedation in the emergency department (ED) is common, increases deep sedation in the ICU, and is negatively associated with outcome. Limiting ED deep sedation may, therefore, be a high-yield intervention to improve outcome. However, the feasibility of conducting an adequately powered ED-based clinical sedation trial is unknown. Our objectives were to assess trial feasibility in terms of: 1) recruitment, 2) protocol implementation and practice change, and 3) safety. Patient-centered clinical outcomes were assessed to better plan for a future large-scale clinical trial.

DESIGN

Pragmatic, multicenter ( n = 3), prospective before-after pilot and feasibility trial.

SETTING

The ED and ICUs at three medical centers.

PATIENTS: Consecutive, adult mechanically ventilation ED patients.

INTERVENTIONS: An educational initiative aimed at reliable ED sedation depth documentation and reducing the proportion of deeply sedated patients (primary outcome).

MEASUREMENTS AND MAIN

RESULTS

Sedation-related data in the ED and the first 48 ICU hours were recorded. Deep sedation was defined as a Richmond Agitation-Sedation Scale of -3 to -5 or a Sedation-Agitation Scale of 1-3. One thousand three hundred fifty-six patients were screened; 415 comprised the final population. Lighter ED sedation was achieved in the intervention group, and the proportion of deeply sedated patients was reduced from 60.2% to 38.8% ( p < 0.01). There were no concerning trends in adverse events (i.e., inadvertent extubation, device removal, and awareness with paralysis). Mortality was 10.0% in the intervention group and 20.4% in the preintervention group ( p < 0.01). Compared with preintervention, the intervention group experienced more ventilator-free days [22.0 (9.0) vs 19.9 (10.6)] and ICU-free days [20.8 (8.7) vs 18.1 (10.4)], p < 0.05 for both.

CONCLUSIONS

This pilot trial confirmed the feasibility of targeting the ED in order to improve sedation practices and reduce deep sedation. These findings justify an appropriately powered clinical trial regarding ED-based sedation to improve clinical outcomes.

Для цитирования: Fuller Brian M, Roberts Brian W, Mohr Nicholas M, Faine Brett, Drewry Anne M, Wessman Brian T, Ablordeppey Enyo, Pappal Ryan D, Stephens Robert J, Sewatsky Thomas, Cho Nicholas S, Yan Yan, Kollef Marin H, Carpenter Christopher R, Avidan Michael S. The Feasibility of Implementing Targeted SEDation in Mechanically Ventilated Emergency Department Patients: The ED-SED Pilot Trial.. Critical care medicine. 2022. DOI: 10.1097/ccm.0000000000005558.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.