Risk factors and prognostic impact of left ventricular assist device-associated infections.

Tattevin Pierre, Flécher Erwan, Auffret Vincent, Leclercq Christophe, Boulé Stéphane, Vincentelli André, Dambrin Camille, Delmas Clément, Barandon Laurent, Veniard Vincent, Kindo Michel, Cardi Thomas, Gaudard Philippe, Rouvière Philippe, Sénage Thomas, Jacob Nicolas, Defaye Pascal, Chavanon Olivier, Verdonk Constance, Para Marylou, Pelcé Edeline, Gariboldi Vlad, Pozzi Matteo, Grinberg Daniel, Savouré Arnaud, Litzler Pierre-Yves, Babatasi Gerard, Belin Annette, Garnier Fabien, Bielefeld Marie, Hamon David, Lellouche Nicolas, Bernard Louis, Bourguignon Thierry, Eschalier Romain, D'Ostrevy Nicolas, Jouan Jérôme, Varlet Emilie, Vanhuyse Fabrice, Blangy Hugues, Martins Raphaël P, Galand Vincent

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Left ventricular assist device (LVAD)-associated infections may be life-threatening and impact patients' outcome. We aimed to identify the characteristics, risk factors, and prognosis of LVAD-associated infections.

METHODS

Patients included in the ASSIST-ICD study (19 centers) were enrolled. The main outcome was the occurrence of LVAD-associated infection (driveline infection, pocket infection, or pump/cannula infection) during follow-up.

RESULTS

Of the 652 patients enrolled, 201 (30.1%) presented a total of 248 LVAD infections diagnosed 6.5 months after implantation, including 171 (26.2%), 51 (7.8%), and 26 (4.0%) percutaneous driveline infection, pocket infection, or pump/cannula infection, respectively. Patients with infections were aged 58.7 years, and most received HeartMate II (82.1%) or HeartWare (13.4%). Most patients (62%) had implantable cardioverter-defibrillators (ICDs) before LVAD, and 104 (16.0%) had ICD implantation, extraction, or replacement after the LVAD surgery. Main pathogens found among the 248 infections were Staphylococcus aureus (n = 113' 45.4%), Enterobacteriaceae (n = 61; 24.6%), Pseudomonas aeruginosa (n = 34; 13.7%), coagulase-negative staphylococci (n = 13; 5.2%), and Candida species (n = 13; 5.2%). In multivariable analysis, HeartMate II (subhazard ratio, 1.56; 95% CI, 1.03 to 2.36; P = .031) and ICD-related procedures post-LVAD (subhazard ratio, 1.43; 95% CI, 1.03-1.98; P = .031) were significantly associated with LVAD infections. Infections had no detrimental impact on survival.

CONCLUSIONS

Left ventricular assist device-associated infections affect one-third of LVAD recipients, mostly related to skin pathogens and gram-negative bacilli, with increased risk with HeartMate II as compared with HeartWare, and in patients who required ICD-related procedures post-LVAD. This is a plea to better select patients needing ICD implantation/replacement after LVAD implantation.

Для цитирования: Tattevin Pierre, Flécher Erwan, Auffret Vincent, Leclercq Christophe, Boulé Stéphane, Vincentelli André, Dambrin Camille, Delmas Clément, Barandon Laurent, Veniard Vincent, Kindo Michel, Cardi Thomas, Gaudard Philippe, Rouvière Philippe, Sénage Thomas, Jacob Nicolas, Defaye Pascal, Chavanon Olivier, Verdonk Constance, Para Marylou, Pelcé Edeline, Gariboldi Vlad, Pozzi Matteo, Grinberg Daniel, Savouré Arnaud, Litzler Pierre-Yves, Babatasi Gerard, Belin Annette, Garnier Fabien, Bielefeld Marie, Hamon David, Lellouche Nicolas, Bernard Louis, Bourguignon Thierry, Eschalier Romain, D'Ostrevy Nicolas, Jouan Jérôme, Varlet Emilie, Vanhuyse Fabrice, Blangy Hugues, Martins Raphaël P, Galand Vincent. Risk factors and prognostic impact of left ventricular assist device-associated infections.. American heart journal. 2019. DOI: 10.1016/j.ahj.2019.04.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.