MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14740338.2018.1442431

Медицинская библиотека · Expert opinion on drug safety · 2018

The nature, magnitude, and reporting compliance of device-related events for intravenous patient-controlled analgesia in the FDA Manufacturer and User Facility Device Experience (MAUDE) database.

Lawal Oluwadolapo D, Mohanty Maitreyee, Elder Harrison, Skeer Margie, Erpelding Nathalie, Lanier Ryan, Katz Nathaniel

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The aim of this study is to determine the characteristics, magnitude, and the quality of reporting of mandated events involving intravenous patient-controlled analgesia (IV-PCA) devices in the Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database; a postmarket surveillance system.

METHODS

We utilized a mixed-methods approach to systematically characterize structured data and text narratives associated with IV-PCA events submitted to MAUDE between 1 January 2011 and 12 September 2016.

RESULTS

Of 1,430 IV-PCA events reported during the study period, 6.4% were adverse events (AEs) as identified via structured data fields in the MEDWATCH forms. Upon qualitative review of the narrative texts, 11.0% of events were associated with an unfavorable clinical outcome, which was 71% higher than the incidence of the adverse outcomes reported using the structured data fields. Device-related issues, which were mostly preventable, accounted for 86.9% of events. Of 65 reportable events submitted by manufacturers, 18.5% did not comply with reporting requirements as mandated by law.

CONCLUSION

Patients on IV-PCA continue to experience serious complications as a result of preventable errors. Multi-modal interventions including educational training and the development and adoption of PCA devices with improved safety features are needed to improve safety.

Для цитирования: Lawal Oluwadolapo D, Mohanty Maitreyee, Elder Harrison, Skeer Margie, Erpelding Nathalie, Lanier Ryan, Katz Nathaniel. The nature, magnitude, and reporting compliance of device-related events for intravenous patient-controlled analgesia in the FDA Manufacturer and User Facility Device Experience (MAUDE) database.. Expert opinion on drug safety. 2018. DOI: 10.1080/14740338.2018.1442431.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.