Operative strategies to reduce cerebral embolic events during on- and off-pump coronary artery bypass surgery: A stratified, prospective randomized trial.

Halkos Michael E, Anderson Aaron, Binongo Jose Nilo G, Stringer Anthony, Lasanajak Yi, Thourani Vinod H, Lattouf Omar M, Guyton Robert A, Baio Kim T, Sarin Eric, Keeling William B, Cook N Renee, Carssow Katherine, Neill Alexis, Glas Kathryn E, Puskas John D

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To determine the impact of different aortic clamping strategies on the incidence of cerebral embolic events during coronary artery bypass grafting (CABG).

METHODS

Between 2012 and 2015, 142 patients with low-grade aortic disease (epiaortic ultrasound grade I/II) undergoing primary isolated CABG were studied. Those undergoing off-pump CABG were randomized to a partial clamp (n = 36) or clampless facilitating device (CFD; n = 36) strategy. Those undergoing on-pump CABG were randomized to a single-clamp (n = 34) or double-clamp (n = 36) strategy. Transcranial Doppler ultrasonography (TCD) was performed to identify high-intensity transient signals (HITS) in the middle cerebral arteries during periods of aortic manipulation. Neurocognitive testing was performed at baseline and 30-days postoperatively. The primary endpoint was total number of HITS detected by TCD. Groups were compared using the Mann-Whitney U test.

RESULTS

In the off-pump group, the median number of total HITS were higher in the CFD subgroup (30.0; interquartile range [IQR], 22-43) compared with the partial clamp subgroup (7.0; IQR, 0-16; P < .0001). In the CFD subgroup, the median number of total HITS was significantly lower for patients with 1 CFD compared with patients with >1 CFD (12.5 [IQR, 4-19] vs 36.0 [IQR, 25-47]; P = .001). In the on-pump group, the median number of total HITS was 10.0 (IQR, 3-17) in the single-clamp group, compared with 16.0 (IQR, 4-49) in the double-clamp group (P = .10). There were no differences in neurocognitive outcomes across the groups.

CONCLUSIONS

For patients with low-grade aortic disease, the use of CFDs was associated with an increased rate of cerebral embolic events compared with partial clamping during off-pump CABG. A single-clamp strategy during on-pump CABG did not significantly reduce embolic events compared with a double-clamp strategy.

Для цитирования: Halkos Michael E, Anderson Aaron, Binongo Jose Nilo G, Stringer Anthony, Lasanajak Yi, Thourani Vinod H, Lattouf Omar M, Guyton Robert A, Baio Kim T, Sarin Eric, Keeling William B, Cook N Renee, Carssow Katherine, Neill Alexis, Glas Kathryn E, Puskas John D. Operative strategies to reduce cerebral embolic events during on- and off-pump coronary artery bypass surgery: A stratified, prospective randomized trial.. The Journal of thoracic and cardiovascular surgery. 2017. DOI: 10.1016/j.jtcvs.2017.04.089.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.