MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrc.2017.02.035

Медицинская библиотека · Journal of critical care · 2017

Incidence of central venous catheter hub contamination.

Holroyd Julie L, Vasilopoulos Terrie, Rice Mark J, Rand Kenneth H, Fahy Brenda G

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate microorganisms causing central venous catheter contamination and how this contamination differs across different catheter metrics.

MATERIALS AND

METHODS

After obtaining IRB approval and informed consent, 830 cultures were prospectively obtained from 45 ICU patients with central venous catheter or peripherally inserted central catheter. Bacterial colonies were identified by mass spectrometry.

RESULTS

Bacterial contamination of central catheter hubs occurred 44% of the time in this study in the ICU setting. Coagulase-positive staphylococci cultures had higher median (±interquartile range) CFUs (12±232) versus coagulase-negative (3±10) and other bacteria (1±3; P<0.001). Bacterial contamination was associated with various metrics. Higher incidence (P<0.05) of coagulase-positive staphylococci cultures was associated with hub-only connections (a "hub" being a female connection; 10.9% vs. 7.9% male connections), connections without a manifold (1lumen device that mixes multiple infusions together; 9.7% vs. 0% with manifold); and central venous pressure monitoring connections (25.8% vs. 7.1% without). Internal jugular sites (10.0% vs. 2.7% femoral, 6.2% PICC, P=0.031) and medial lumens of triple lumen catheters (11.9% vs. 5.6% distal, 7.0% proximal, P=0.049) had increased incidence of higher bacteria loads (>15 CFUs).

CONCLUSIONS

This study found a high incidence of central access catheter hub bacterial contamination, which correlated with positive blood cultures in 2 of 3 total bacteremia cases identified in the 45 patients.

Для цитирования: Holroyd Julie L, Vasilopoulos Terrie, Rice Mark J, Rand Kenneth H, Fahy Brenda G. Incidence of central venous catheter hub contamination.. Journal of critical care. 2017. DOI: 10.1016/j.jcrc.2017.02.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.