m+Medelevator.RU
← Поиск публикаций
Echocardiography (Mount Kisco, N.Y.) · 2012

Multimodality imaging of aortic dimensions: comparison of transthoracic echocardiography with multidetector row computed tomography.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tsang James F, Lytwyn Matthew, Farag Ashraf, Zeglinski Matthew, Wallace Kerrett, daSilva Megan, Bohonis Sheena, Walker Jonathan R, Tam James W, Strzelczyk Jacek, Jassal Davinder S

Аннотация

BACKGROUND: With recent advances in multimodality cardiac imaging, a number of methods exist for the noninvasive assessment of aortic disease. Although multidetector row computed tomography (MDCT) remains the gold standard for aortic measurements, there are a number of limitations including radiation and contrast-induced nephropathy. Transthoracic echocardiography (TTE) is an alternative to MDCT for providing accurate anatomic assessment of aortic root and ascending aorta dimensions.

OBJECTIVES AND METHODS: To determine the accuracy of two-dimensional (2D) TTE for determining aortic measurements in comparison to MDCT, a retrospective study of individuals with varying aortic root and ascending aorta dimensions was performed.

RESULTS: There were 116 patients (77 males, mean age 49 ± 12 years) in total. The maximum aortic diameters by 2D TTE were 26.1 ± 4.3 mm (annulus), 32.4 ± 5.6 mm (sinuses), 30.1 ± 5.9 mm (sinotubular [ST] junction), and 33.4 ± 7.3 mm (ascending aorta). The maximum aortic diameters by MDCT were 30.1 ± 4.1 mm (annulus), 35.8 ± 5.8 mm (sinuses), 33.2 ± 5.9 mm (ST junction), and 37.4 ± 7.6 mm (ascending aorta). There was good to excellent correlation between 2D TTE and MDCT at all four levels of the aorta (annulus: r = 0.84; sinuses: r = 0.93; ST junction: r = 0.93; ascending aorta: r = 0.88). There was a consistent underestimation of aortic measurements obtained by 2D TTE when compared to MDCT.

CONCLUSION: 2DTTE is a feasible, accurate, and reproducible method for the noninvasive assessment of thoracic aortic diameters as compared to MDCT.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты