MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8175.2012.01666.x

Медицинская библиотека · Echocardiography (Mount Kisco, N.Y.) · 2012

Multimodality imaging of aortic dimensions: comparison of transthoracic echocardiography with multidetector row computed tomography.

Tsang James F, Lytwyn Matthew, Farag Ashraf, Zeglinski Matthew, Wallace Kerrett, daSilva Megan, Bohonis Sheena, Walker Jonathan R, Tam James W, Strzelczyk Jacek, Jassal Davinder S

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

With recent advances in multimodality cardiac imaging, a number of methods exist for the noninvasive assessment of aortic disease. Although multidetector row computed tomography (MDCT) remains the gold standard for aortic measurements, there are a number of limitations including radiation and contrast-induced nephropathy. Transthoracic echocardiography (TTE) is an alternative to MDCT for providing accurate anatomic assessment of aortic root and ascending aorta dimensions.

OBJECTIVES AND

METHODS

To determine the accuracy of two-dimensional (2D) TTE for determining aortic measurements in comparison to MDCT, a retrospective study of individuals with varying aortic root and ascending aorta dimensions was performed.

RESULTS

There were 116 patients (77 males, mean age 49 ± 12 years) in total. The maximum aortic diameters by 2D TTE were 26.1 ± 4.3 mm (annulus), 32.4 ± 5.6 mm (sinuses), 30.1 ± 5.9 mm (sinotubular [ST] junction), and 33.4 ± 7.3 mm (ascending aorta). The maximum aortic diameters by MDCT were 30.1 ± 4.1 mm (annulus), 35.8 ± 5.8 mm (sinuses), 33.2 ± 5.9 mm (ST junction), and 37.4 ± 7.6 mm (ascending aorta). There was good to excellent correlation between 2D TTE and MDCT at all four levels of the aorta (annulus: r = 0.84; sinuses: r = 0.93; ST junction: r = 0.93; ascending aorta: r = 0.88). There was a consistent underestimation of aortic measurements obtained by 2D TTE when compared to MDCT.

CONCLUSION

2DTTE is a feasible, accurate, and reproducible method for the noninvasive assessment of thoracic aortic diameters as compared to MDCT.

Для цитирования: Tsang James F, Lytwyn Matthew, Farag Ashraf, Zeglinski Matthew, Wallace Kerrett, daSilva Megan, Bohonis Sheena, Walker Jonathan R, Tam James W, Strzelczyk Jacek, Jassal Davinder S. Multimodality imaging of aortic dimensions: comparison of transthoracic echocardiography with multidetector row computed tomography.. Echocardiography (Mount Kisco, N.Y.). 2012. DOI: 10.1111/j.1540-8175.2012.01666.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.