MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.knee.2012.04.004

Медицинская библиотека · The Knee · 2012

MRI after unicondylar knee arthroplasty: the preserved compartments.

Heyse Thomas J, Figiel Jens, Hähnlein Ulrike, Timmesfeld Nina, Schmitt Jan, Schofer Markus D, Fuchs-Winkelmann Susanne, Efe Turgay

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this study was to assess the reproducibility of using magnetic resonance imaging (MRI) to analyze the preserved anatomic knee compartments following unicondylar knee arthroplasty (UKA) with zirconium femoral components. It was hypothesized that evaluation of the cartilage, ligaments, meniscus, and tendons would result in a high rate of inter-observer reliability.

SCOPE: Ten patients underwent MRI of the knee tailored to reduce metallic artifact following medial UKA with zirconium femoral implants. Cartilage, external meniscus, collateral and cruciate ligaments, the quadriceps and patellar tendons, and the presence of joint effusion were evaluated by two independent investigators. The reviewers provided degrees of confidence with their evaluation of each parameter through the use of a five-point scale. Inter-observer agreement was calculated and inter-observer reliability was determined by use of Cohen's Kappa. Artifacts originating from the implants were rarely observed. There was excellent inter-observer reliability (i.e., high Cohen's Kappa) for all assessed structures, and a high level of observer confidence for the evaluation of the cartilage, meniscus, tendons, ligaments, and joint effusion.

CONCLUSION

In this study tailored MRI allows for reproducible analysis of the preserved knee joint compartment after UKA for zirconium implants. This technique might prove helpful in the assessment of painful knee joints after UKA with other metallic materials as new MRI software programs, which suppress metal artifacts, are developed.

Для цитирования: Heyse Thomas J, Figiel Jens, Hähnlein Ulrike, Timmesfeld Nina, Schmitt Jan, Schofer Markus D, Fuchs-Winkelmann Susanne, Efe Turgay. MRI after unicondylar knee arthroplasty: the preserved compartments.. The Knee. 2012. DOI: 10.1016/j.knee.2012.04.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.