MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.70527

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026

Physiologic Assessment Using Angiography-Derived Fractional Flow Reserve After Drug-Coated Balloon Angioplasty in De Novo Coronary Lesions.

Chang Chun-Chin, Lee Jui-Yun, Chou Hsin Lin, Sung Wei-Ting, Lu Ya-Wen, Tsai Yi-Lin, Teng Hsin-I, Chou Ruey-Hsing, Aben Jean-Paul, Huang Po-Hsun

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGORUND: Drug-coated balloon (DCB) angioplasty offers a potential alternative to avoid permanent metallic stent implantation and the associated risk of in-stent restenosis.

AIMS: This study aimed to evaluate the safety and effectiveness of DCB angioplasty for de novo coronary stenoses in real-world clinical practice.

METHODS

This was a single-center, retrospective observational study. Between March 2017 and October 2023, patients who underwent DCB angioplasty for at least one de novo coronary stenosis were included. The primary endpoint was the device-oriented composite endpoint (DOCE), defined as a composite of cardiovascular death, device failure-related myocardial infarction, or device failure-related target lesion revascularization. Post-procedural angiography-derived fractional flow reserve (vFFR) was evaluated after DCB angioplasty in eligible patients with angiograms of adequate quality.

RESULTS

A total of 255 de novo coronary stenoses undergoing DCB angioplasty were analyzed. Among the treated lesions, 92.5% were located in the main epicardial vessels. Cutting or scoring balloons and rotational atherectomy were employed for lesion preparation in 14.5% and 5.9% of lesions, respectively. The bailout stenting rate was 1.9%. During a follow-up duration of 558 ± 499 days, the primary endpoint, DOCE, occurred in 13 lesions (5.1%). Post-procedural vFFR was analyzable in 130 lesions. Residual stenosis ≤ 30% was achieved in only 39.1% of lesions, whereas 80.7% of lesions demonstrated a post-procedural vFFR ≥ 0.75.

CONCLUSIONS

Patients undergoing DCB angioplasty for de novo coronary stenoses demonstrated favorable clinical outcomes during mid-term follow-up. The clinical utility of vFFR in the context of DCB angioplasty warrants further investigation in large-scale studies to determine its impact on clinical outcomes.

Для цитирования: Chang Chun-Chin, Lee Jui-Yun, Chou Hsin Lin, Sung Wei-Ting, Lu Ya-Wen, Tsai Yi-Lin, Teng Hsin-I, Chou Ruey-Hsing, Aben Jean-Paul, Huang Po-Hsun. Physiologic Assessment Using Angiography-Derived Fractional Flow Reserve After Drug-Coated Balloon Angioplasty in De Novo Coronary Lesions.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2026. DOI: 10.1002/ccd.70527.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.