MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2025.09.036

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2025

Influence of effective orifice area on long-term survival in bioprosthetic versus mechanical aortic valves.

Danesh Sina, Tam Vincy, Lee Aurora, Sawma Tedy, Arghami Arman, Stulak John M, Rowse Philip, Holst Kimberly, Todd Austin, Greason Kevin L, Shrestha Malakh, Bagameri Gabor, Pochettino Alberto, Nkomo Vuyisile T, Pislaru Sorin V, Eleid Mackram F, Gulati Rajiv, Guerrero Mayra, Simard Trevor, Dearani Joseph A, Crestanello Juan A, Tang Paul C

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

We examined the potential influence of effective orifice area (EOA) and EOA index (EOAi) on survival between bioprosthetic and mechanical valves.

METHODS

We analyzed 3265 patients aged 75 years or younger undergoing aortic valve replacement with or without coronary artery bypass grafting. EOA and EOAi were obtained from predischarge echocardiograms. Bootstrapped logistic regression and restricted cubic splines identified optimal survival cut points for EOA and EOAi. Multivariable Cox proportional hazards models were fitted, and adjusted Kaplan-Meier survival curves were generated using the identified EOA cut points.

RESULTS

The mechanical aortic valve replacement group was younger (age 60 vs 69 years; P < .001). For mechanical and bioprosthetic aortic valve replacement groups, respectively, the median EOA was (2.0 cm2; range, 1.6-2.4 vs 2.1 cm2; range, 1.7-2.6 cm2; P < .001) and EOA index was (1.0 cm2/m2; range, 0.8-1.2 cm2/m2 vs 1.1 cm2/m2, range, 0.9-1.3 cm2/m2; P < .001) In patients with EOA ≥2 cm2, long-term adjusted risk of mortality was higher in the bioprosthesis group compared with the mechanical group (hazard ratio, 1.33; P = .010). However, no significant difference was observed for those with EOA <2 cm2 (hazard ratio, 1.01; 95% CI, 0.83-1.23; P = .932). Similarly, for EOA index ≥1.08 cm2/m2, the bioprosthesis group was associated with higher risk of long-term mortality (hazard ratio, 1.29; 95% CI, 1.01-1.64, P = .040), whereas no significant association was found for those with an EOA index <1.08 cm2/m2 (hazard ratio, 1.05; P = .621).

CONCLUSIONS

In this cohort, there was a survival advantage of mechanical valves over bioprostheses in larger valve sizes but not in patients with smaller EOA metrics.

Для цитирования: Danesh Sina, Tam Vincy, Lee Aurora, Sawma Tedy, Arghami Arman, Stulak John M, Rowse Philip, Holst Kimberly, Todd Austin, Greason Kevin L, Shrestha Malakh, Bagameri Gabor, Pochettino Alberto, Nkomo Vuyisile T, Pislaru Sorin V, Eleid Mackram F, Gulati Rajiv, Guerrero Mayra, Simard Trevor, Dearani Joseph A, Crestanello Juan A, Tang Paul C. Influence of effective orifice area on long-term survival in bioprosthetic versus mechanical aortic valves.. The Journal of thoracic and cardiovascular surgery. 2025. DOI: 10.1016/j.jtcvs.2025.09.036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.