m+Medelevator.RU
← Поиск публикаций
Interventional radiology (Higashimatsuyama-shi (Japan) · 2024

Large-bore Chest Tube Insertion: Seldinger Technique over Two Guidewires.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Saiga Atsushi, Aramaki Takeshi, Sato Rui

Аннотация

PURPOSE: Large-bore chest tube insertion is commonly performed using the trocar technique and blunt dissection; however, large-bore chest tube can cause severe visceral injury due to penetration, which is a life-threatening complication. Conversely, small-bore chest tubes can be safely inserted using the Seldinger technique; however, small-bore chest tubes are prone to blockage, especially in empyema cases. Therefore, this study aimed to demonstrate large-bore chest tube insertion using the Seldinger technique over two guidewires following image-guided puncture.

MATERIAL AND METHODS: We started performing large-bore chest tube insertion using the Seldinger technique over two guidewires following image-guided puncture in February 2022. Demographic data and procedural details, such as chest tube size, dilator size, procedure time, and type of image-guided puncture, of patients who underwent this procedure between February 2022 and March 2023 were retrospectively reviewed. Technical success was defined as the successful drainage of the pleural cavity.

RESULTS: This method was used for performing ten procedures in nine patients who presented with empyema, pneumothorax, and pulmonary fistula. The insertion of a large-bore chest tube with a size ranging from 18- to 24-French was successfully performed in all cases without any complications. The median procedure time was 17.5 (first quartile-third quartile, 13.5-28.0) min.

CONCLUSIONS: Large-bore chest tube insertion using the Seldinger technique over two guidewires may be used as an alternative to conventional methods.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты