Transbronchial Cryobiopsy Versus Transbronchial Forceps Biopsy for Acute Cellular Rejection Detection in Lung Transplantation: A Meta-Analysis.

Luo Yan, Li Sheng-Ping

СтатьяМетаанализСистематический обзорСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Transbronchial cryobiopsy (TBCB) provides larger tissue samples and improved sampling depth, but its role in diagnosing acute cellular rejection (ACR) in lung transplant patients is unclear due to limitations in existing studies. To address this, we conducted a systematic review and meta-analysis to evaluate the efficacy and safety of TBCB.

METHODS

A thorough literature review was conducted to evaluate TBCB in post-lung transplant surveillance, assessing the quality of studies and conducting a meta-analysis comparing diagnostic yields of TBCB and transbronchial forceps biopsy (TBFB), as well as evaluating procedural complications.

RESULTS

Our meta-analysis, incorporating 11 studies with a total of 915 patients, showed that TBCB had a diagnostic rate of 38.27% (225/588) for ACR post-lung transplantation, notably higher than the 35.65% (251/704) for TBFB. The inverse-variance weighted odds ratio was calculated at 2.32 (95% confidence interval: 1.24-4.32; p=0.008). Funnel plot analysis indicated no major publication bias. Meta-analysis of 6 studies demonstrated that TBCB, compared to TBFB, significantly increased the diagnostic rate for chronic rejection post-transplantation (25.00% vs 10.93%, p=0.005). Our meta-analysis comparing the safety of TBCB and TBFB in post-lung transplant surveillance found no significant differences in moderate to severe bleeding (5.99% vs 6.31%, p=0.98), or pneumothorax incidence (3.90% vs 3.29%, p=0.75).

CONCLUSIONS

Our study indicates that TBCB may enhance the diagnosis of acute and chronic rejection post-lung transplantation with a safety profile comparable to TBFB. Further research and the development of standardized procedures are warranted to ensure the safe and effective application of TBCB in broader clinical practice.

Для цитирования: Luo Yan, Li Sheng-Ping. Transbronchial Cryobiopsy Versus Transbronchial Forceps Biopsy for Acute Cellular Rejection Detection in Lung Transplantation: A Meta-Analysis.. Archivos de bronconeumologia. 2024. DOI: 10.1016/j.arbres.2024.06.006.