DOI 10.17116/hirurgia202406136
[Navigational bronchoscopy with tranbronchial cryobiopsy in differential diagnosis of peripheral pulmonary lesions].
Аннотация
OBJECTIVE
To evaluate the efficacy and safety of tranbronchial cryobiopsy (TBCB) with 1.9-mm and 1.1-mm cryoprobes in patients with peripheral pulmonary lesions (PPLs).
MATERIAL AND
METHODS
We analyzed 34 patients (mean age 60 years) with PPLs who underwent bronchoscopy with TBCB. Mean lesion size was 31.5 mm, upper lobe localization was predominant (47% of cases). CT signs of appropriate bronchus were identified in 79% (27/34) of cases. Manual branch tracking and virtual bronchoscopy (VB) were performed pre-procedurally, and radial endobronchial ultrasonography (rEBUS) was performed during bronchoscopy for accurate positioning of PPLs. TBCB was performed using 1.9-mm (n=19) or 1.1-mm (n=15) cryoprobes without fluoroscopic guidance. Incidence and severity of bleeding and pneumothorax were evaluated in all patients.
RESULTS
Total efficacy of TBCB was 76.5% (26/34): 78.9% (15/19) for 1.9-mm cryoprobe and 73.3% (11/15) for 1.1-mm cryoprobe (p=0.702). Efficacy depended on the presence of CT signs of bronchus (presence - 94%, absence 14.3%, p<0.001) and PPL size (94% for PPL >30 mm and 58.8% for PPL <30 mm, p=0.016). Central probe position during rEBUS was associated with 94.7% diagnostic efficacy (18/19), adjacent probe position - 72.7% (8/11) (p=0.088). Bleeding grade 3 (Nasville) occurred in 5.8% (2/34) of cases, and no pneumothorax was observed.
CONCLUSION
TBCB is an effective and safe diagnostic method for PPLs.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.