Diagnostic accuracy of optical coherence tomography for the identification of in-stent fibroatheroma following stent implantation: an ex vivo histological validation study.

Shibutani Hiroki, Fujii Kenichi, Kawakami Rika, Imanaka Takahiro, Kawai Kenji, Tsujimoto Satoshi, Matsumura Koichiro, Otagaki Munemitsu, Morishita Shun, Hashimoto Kenta, Hao Hiroyuki, Hirota Seiichi, Shiojima Ichiro

СтатьяПеревод пока не подготовлен

Аннотация

The accurate identification of in-stent fibroatheroma by in vivo imaging is clinically important to preventing the late catch-up phenomenon after stent deployment. This study investigated the diagnostic accuracy of optical coherence tomography (OCT) for the detection of "in-stent fibroatheroma" following stent implantation. Fifty stented coronary arteries from the 31 autopsy hearts were examined to compare OCT and histological image findings. A histological in-stent fibroatheroma was defined as a neointima containing an acellular necrotic core generated by macrophage infiltration. OCT-derived in-stent fibroatheroma comprised a heterogeneous pattern with an invisible stent strut behind the low-signal-intensity region. A total of 122 matched OCT and histology cross-sections were evaluated. Using histological findings as the gold standard, the sensitivity, specificity, positive predictive value, and negative predictive value for OCT-derived in-stent fibroatheroma were 100%, 99%, 80%, and 100%, respectively. The only histological finding underlying the false-positive diagnosis of OCT-derived in-stent fibroatheroma was foam cell accumulation without a necrotic core on the neointimal surface. No false-negative diagnosis of OCT for in-stent fibroatheroma was apparent in this analysis. This study demonstrated the potential capability of OCT based on stent strut visualization behind low-signal-intensity regions to discriminate in-stent fibroatheroma from other neointimal tissues.

Для цитирования: Shibutani Hiroki, Fujii Kenichi, Kawakami Rika, Imanaka Takahiro, Kawai Kenji, Tsujimoto Satoshi, Matsumura Koichiro, Otagaki Munemitsu, Morishita Shun, Hashimoto Kenta, Hao Hiroyuki, Hirota Seiichi, Shiojima Ichiro. Diagnostic accuracy of optical coherence tomography for the identification of in-stent fibroatheroma following stent implantation: an ex vivo histological validation study.. The international journal of cardiovascular imaging. 2021. DOI: 10.1007/s10554-020-02125-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.