AJR. American journal of roentgenology · 2023
High-Speed On-Site Deep Learning-Based FFR-CT Algorithm: Evaluation Using Invasive Angiography as the Reference Standard.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Giannopoulos Andreas A, Keller Lukas, Sepulcri Daniel, Boehm Reto, Garefa Chrysoula, Venugopal Prem, Mitra Jhimli, Ghose Soumya, Deak Paul, Pack Jed D, Davis Cynthia L, Stähli Barbara E, Stehli Julia, Pazhenkottil Aju P, Kaufmann Philipp A, Buechel Ronny R
Аннотация
BACKGROUND. Estimation of fractional flow reserve from coronary CTA (FFR-CT) is an established method of assessing the hemodynamic significance of coronary lesions. However, clinical implementation has progressed slowly, partly because of off-site data transfer with long turnaround times for results. OBJECTIVE. The purpose of this study was to evaluate the diagnostic performance of FFR-CT computed on-site with a high-speed deep learning-based algorithm with invasive hemodynamic indexes as the reference standard. METHODS. This retrospective study included 59 patients (46 men, 13 women; mean age, 66.5 ± 10.2 years) who underwent coronary CTA (including calcium scoring) followed within 90 days by invasive angiography with invasive fractional flow reserve (FFR) and/or instantaneous wave-free ratio measurements from December 2014 to October 2021. Coronary artery lesions were considered to have hemodynamically significant stenosis in the presence of invasive FFR of 0.80 or less and/or instantaneous wave-free ratio of 0.89 or less. A single cardiologist evaluated the CTA images using an on-site deep learning-based semiautomated algorithm entailing a 3D computational flow dynamics model to determine FFR-CT for coronary artery lesions detected with invasive angiography. Time for FFR-CT analysis was recorded. FFR-CT analysis was repeated by the same cardiologist in 26 randomly selected examinations and by a different cardiologist in 45 randomly selected examinations. Diagnostic performance and agreement were assessed. RESULTS. A total of 74 lesions were identified with invasive angiography. FFR-CT and invasive FFR had strong correlation (r = 0.81) and, in Bland-Altman analysis, bias of 0.01 and 95% limits of agreement of -0.13 to 0.15. FFR-CT had AUC for hemodynamically significant stenosis of 0.975. At a cutoff of 0.80 or less, FFR-CT had 95.9% accuracy, 93.5% sensitivity, and 97.7% specificity. In 39 lesions with severe calcifications (≥ 400 Agatston units), FFR-CT had AUC of 0.991 and at a cutoff of 0.80, 94.7% sensitivity, 95.0% specificity, and 94.9% accuracy. Mean analysis time per patient was 7 minutes 54 seconds. Intraobserver agreement (intraclass correlation coefficient, 0.85; bias, -0.01; 95% limits of agreement, -0.12 and 0.10) and interobserver agreement (intraclass correlation coefficient, 0.94; bias, -0.01; 95% limits of agreement, -0.08 and 0.07) were good to excellent. CONCLUSION. A high-speed on-site deep learning-based FFR-CT algorithm had excellent diagnostic performance for hemodynamically significant stenosis with high reproducibility. CLINICAL IMPACT. The algorithm should facilitate implementation of FFR-CT technology into routine clinical practice.