MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcmg.2023.02.005

Медицинская библиотека · JACC. Cardiovascular imaging · 2023

The Use and Efficacy of FFR-CT: Real-World Multicenter Audit of Clinical Data With Cost Analysis.

Mittal Tarun K, Hothi Sandeep S, Venugopal Vinod, Taleyratne John, O'Brien David, Adnan Kazi, Sehmi Joban, Daskalopoulos Georgios, Deshpande Aparna, Elfawal Sara, Sharma Vinoda, Shahin Rajai A, Yuan Mengshi, Schlosshan Dominik, Walker Andrew, Abdel Rahman Saif-El-Dean, Sunderji Imran, Wagh Sidhesh, Chow Jocelyn, Masood Mohammed, Sharma Sumeet, Agrawal Sharad, Duraikannu Chary, McAlindon Elisa, Mirsadraee Saeed, Nicol Edward D, Kelion Andrew D

Многоцентровое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Fractional flow reserve-computed tomography (FFR-CT) is endorsed by UK and U.S. chest pain guidelines, but its clinical effectiveness and cost benefit in real-world practice are unknown.

OBJECTIVES

The purpose of this study was to audit the use of FFR-CT in clinical practice against England's National Institute for Health and Care Excellence guidance and assess its diagnostic accuracy and cost.

METHODS

A multicenter audit was undertaken covering the 3 years when FFR-CT was centrally funded in England. For coronary computed tomographic angiograms (CCTAs) submitted for FFR-CT analysis, centers provided data on symptoms, CCTA and FFR-CT findings, and subsequent management. Audit standards included using FFR-CT only in patients with stable chest pain and equivocal stenosis (50%-69%). Diagnostic accuracy was evaluated against invasive FFR, when performed. Follow-up for nonfatal myocardial infarction and all-cause mortality was undertaken. The cost of an FFR-CT strategy was compared to alternative stress imaging pathways using cost analysis modeling.

RESULTS

A total of 2,298 CCTAs from 12 centers underwent FFR-CT analysis. Stable chest pain was the main symptom in 77%, and 40% had equivocal stenosis. Positive and negative predictive values of FFR-CT were 49% and 76%, respectively. A total of 46 events (2%) occurred over a mean follow-up period of 17 months; FFR-CT (cutoff: 0.80) was not predictive. The FFR-CT strategy costs £2,102 per patient compared with an average of £1,411 for stress imaging.

CONCLUSIONS

In clinical practice, the National Institute for Health and Care Excellence criteria for using FFR-CT were met in three-fourths of patients for symptoms and 40% for stenosis. FFR-CT had a low positive predictive value, making its use potentially more expensive than conventional stress imaging strategies.

Для цитирования: Mittal Tarun K, Hothi Sandeep S, Venugopal Vinod, Taleyratne John, O'Brien David, Adnan Kazi, Sehmi Joban, Daskalopoulos Georgios, Deshpande Aparna, Elfawal Sara, Sharma Vinoda, Shahin Rajai A, Yuan Mengshi, Schlosshan Dominik, Walker Andrew, Abdel Rahman Saif-El-Dean, Sunderji Imran, Wagh Sidhesh, Chow Jocelyn, Masood Mohammed, Sharma Sumeet, Agrawal Sharad, Duraikannu Chary, McAlindon Elisa, Mirsadraee Saeed, Nicol Edward D, Kelion Andrew D. The Use and Efficacy of FFR-CT: Real-World Multicenter Audit of Clinical Data With Cost Analysis.. JACC. Cardiovascular imaging. 2023. DOI: 10.1016/j.jcmg.2023.02.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало