PloS one · 2023
Patient-specific computational simulation of coronary artery bypass grafting.
СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wu Wei, Panagopoulos Anastasios Nikolaos, Vasa Charu Hasini, Sharzehee Mohammadali, Zhao Shijia, Samant Saurabhi, Oguz Usama M, Khan Behram, Naser Abdallah, Harmouch Khaled M, Kassab Ghassan S, Siddique Aleem, Chatzizisis Yiannis S
Аннотация
INTRODUCTION: Coronary artery bypass graft surgery (CABG) is an intervention in patients with extensive obstructive coronary artery disease diagnosed with invasive coronary angiography. Here we present and test a novel application of non-invasive computational assessment of coronary hemodynamics before and after bypass grafting.
METHODS AND RESULTS: We tested the computational CABG platform in n = 2 post-CABG patients. The computationally calculated fractional flow reserve showed high agreement with the angiography-based fractional flow reserve. Furthermore, we performed multiscale computational fluid dynamics simulations of pre- and post-CABG under simulated resting and hyperemic conditions in n = 2 patient-specific anatomies 3D reconstructed from coronary computed tomography angiography. We computationally created different degrees of stenosis in the left anterior descending artery, and we showed that increasing severity of native artery stenosis resulted in augmented flow through the graft and improvement of resting and hyperemic flow in the distal part of the grafted native artery.
CONCLUSIONS: We presented a comprehensive patient-specific computational platform that can simulate the hemodynamic conditions before and after CABG and faithfully reproduce the hemodynamic effects of bypass grafting on the native coronary artery flow. Further clinical studies are warranted to validate this preliminary data.
METHODS AND RESULTS: We tested the computational CABG platform in n = 2 post-CABG patients. The computationally calculated fractional flow reserve showed high agreement with the angiography-based fractional flow reserve. Furthermore, we performed multiscale computational fluid dynamics simulations of pre- and post-CABG under simulated resting and hyperemic conditions in n = 2 patient-specific anatomies 3D reconstructed from coronary computed tomography angiography. We computationally created different degrees of stenosis in the left anterior descending artery, and we showed that increasing severity of native artery stenosis resulted in augmented flow through the graft and improvement of resting and hyperemic flow in the distal part of the grafted native artery.
CONCLUSIONS: We presented a comprehensive patient-specific computational platform that can simulate the hemodynamic conditions before and after CABG and faithfully reproduce the hemodynamic effects of bypass grafting on the native coronary artery flow. Further clinical studies are warranted to validate this preliminary data.