MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.compbiomed.2022.106484

Медицинская библиотека · Computers in biology and medicine · 2022

A token-mixer architecture for CAD-RADS classification of coronary stenosis on multiplanar reconstruction CT images.

Penso Marco, Moccia Sara, Caiani Enrico G, Caredda Gloria, Lampus Maria Luisa, Carerj Maria Ludovica, Babbaro Mario, Pepi Mauro, Chiesa Mattia, Pontone Gianluca

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

In patients with suspected Coronary Artery Disease (CAD), the severity of stenosis needs to be assessed for precise clinical management. An automatic deep learning-based algorithm to classify coronary stenosis lesions according to the Coronary Artery Disease Reporting and Data System (CAD-RADS) in multiplanar reconstruction images acquired with Coronary Computed Tomography Angiography (CCTA) is proposed.

METHODS

In this retrospective study, 288 patients with suspected CAD who underwent CCTA scans were included. To model long-range semantic information, which is needed to identify and classify stenosis with challenging appearance, we adopted a token-mixer architecture (ConvMixer), which can learn structural relationship over the whole coronary artery. ConvMixer consists of a patch embedding layer followed by repeated convolutional blocks to enable the algorithm to learn long-range dependences between pixels. To visually assess ConvMixer performance, Gradient-Weighted Class Activation Mapping (Grad-CAM) analysis was used.

RESULTS

Experimental results using 5-fold cross-validation showed that our ConvMixer can classify significant coronary artery stenosis (i.e., stenosis with luminal narrowing ≥50%) with accuracy and sensitivity of 87% and 90%, respectively. For CAD-RADS 0 vs. 1-2 vs. 3-4 vs. 5 classification, ConvMixer achieved accuracy and sensitivity of 72% and 75%, respectively. Additional experiments showed that ConvMixer achieved a better trade-off between performance and complexity compared to pyramid-shaped convolutional neural networks.

CONCLUSIONS

Our algorithm might provide clinicians with decision support, potentially reducing the interobserver variability for coronary artery stenosis evaluation.

Для цитирования: Penso Marco, Moccia Sara, Caiani Enrico G, Caredda Gloria, Lampus Maria Luisa, Carerj Maria Ludovica, Babbaro Mario, Pepi Mauro, Chiesa Mattia, Pontone Gianluca. A token-mixer architecture for CAD-RADS classification of coronary stenosis on multiplanar reconstruction CT images.. Computers in biology and medicine. 2022. DOI: 10.1016/j.compbiomed.2022.106484.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.