Infective endocarditis in patients with cardiac implantable electronic devices: a nationwide study.

Mateos Gaitán Roberto, Boix-Palop Lucía, Muñoz García Patricia, Mestres Carlos A, Marín Arriaza Mercedes, Pedraz Prieto Álvaro, de Alarcón Gonzalez Arístides, Gutiérrez Carretero Encarnación, Hernández Meneses Marta, Goenaga Sánchez Miguel Ángel, Cobo Belaustegui Manuel, Oteo Revuelta José Antonio, Gainzarain Arana Juan Carlos, García Vázquez Elisa, Martínez-Sellés Manuel

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: Patients with infective endocarditis (IE) frequently have cardiac implantable electronic devices (CIEDs). Here, we aim to define the clinical profile and prognostic factors of IE in these patients.

METHODS AND

RESULTS

Infective endocarditis cases were prospectively identified in the Spanish National Endocarditis Registry. From 3996 IE, 708 (17.7%) had a CIED and 424 CIED-related IE (lead vegetation). Patients with a CIED were older (68 ± 11 vs. 73 ± 8 years); had more comorbidities {pulmonary disease [176 (24.8%) vs. 545 (16.7%)], renal disease [239 (33.8%) vs. 740 (22.7%)], diabetes [248 (35.0%) vs. 867 (26.6%)], and heart failure [348 (49.2%) vs. 978 (29.9%)]}; and fewer complications {intracardiac destruction [106 (15%) vs. 1077 (33.1%)], heart failure [215 (30.3%) vs. 1340 (41.1%)], embolism [107 (15.1%) vs. 714 (21.9%)], and neurological involvement [77 (10.8%) vs. 702 (21.5%)]} (all P-values <0.001) in comparison to subjects without a CIED. In-hospital mortality was similar in patients with and without CIED [171 (24.2%) vs. 881 (27.0%), P = 0.82]. In subjects with a CIED, CIED-related IE was independently associated with in-hospital survival: odds ratio (OR) 0.4 [95% confidence interval (CI) 0.3-0.7, P = 0.001]. Surgery was independently associated with in-hospital survival in CIED-related IE: OR 0.4 (95% CI 0.2-0.7, P = 0.004); but not in subjects with valve IE and no CIED lead involvement: OR 0.9 (95% CI 0.5-1.7, P = 0.77).

CONCLUSION

Over a sixth of IE patients have a CIED. This group of patients is older, with more comorbidities and fewer IE-related complications in comparison to subjects without a CIED. In-hospital mortality was similar in patients with and without a CIED.

Для цитирования: Mateos Gaitán Roberto, Boix-Palop Lucía, Muñoz García Patricia, Mestres Carlos A, Marín Arriaza Mercedes, Pedraz Prieto Álvaro, de Alarcón Gonzalez Arístides, Gutiérrez Carretero Encarnación, Hernández Meneses Marta, Goenaga Sánchez Miguel Ángel, Cobo Belaustegui Manuel, Oteo Revuelta José Antonio, Gainzarain Arana Juan Carlos, García Vázquez Elisa, Martínez-Sellés Manuel. Infective endocarditis in patients with cardiac implantable electronic devices: a nationwide study.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2020. DOI: 10.1093/europace/euaa076.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.