MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0000000000001136

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2020

Sternum-Sparing HVAD Implantation with Attachment of the Outflow Graft to the Descending Aorta.

Kawabori Masashi, Critsinelis Andre, Kurihara Chitaru, Sugiura Tadahisa, Morgan Jeffrey A

СтатьяПеревод пока не подготовлен

Аннотация

The standard approach for implanting an HVAD left ventricular assist device (LVAD) is performing a median sternotomy and sewing the outflow graft to the ascending aorta. However, in patients with sternal comorbidities, it may be advantageous to use a sternum-sparing approach. We retrospectively studied eight patients who underwent HVAD implantation for destination therapy via a left subcostal or fifth/sixth intercostal space incision. With this procedure, the outflow graft was sewed to the descending aorta. Ninety-day and one-year survival rates were 87.5% and 75%, respectively. Two patients (25%) died during the perioperative period: one from multisystem organ failure and the other from unrelated causes. We adjusted the HVAD speed to open the aortic valve once every three to four beats. Compared with other continuous-flow LVAD implantations performed at our institution during the study period (n = 437), this technique resulted in shorter bypass times and a lower incidence of infection; it was not associated with an increased incidence of heart failure, aortic root thrombosis, pump thrombosis, progression of aortic insufficiency, or ischemic neurologic dysfunction. Our findings suggest that a sternum-sparing approach for HVAD implantation is feasible and may be a safe option in patients with serious comorbidities that preclude the use of traditional implantation techniques.

Для цитирования: Kawabori Masashi, Critsinelis Andre, Kurihara Chitaru, Sugiura Tadahisa, Morgan Jeffrey A. Sternum-Sparing HVAD Implantation with Attachment of the Outflow Graft to the Descending Aorta.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2020. DOI: 10.1097/mat.0000000000001136.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.