DOI 10.1007/s12020-024-03731-5
Interobserver variability in thyroid ultrasound.
Аннотация
PURPOSE: Ultrasound evaluation of thyroid nodules is the preferred technique, but it is dependent on operator interpretation, leading to inter-observer variability. The current study aimed to determine the inter-physician consensus on nodular characteristics, risk categorization in the classification systems, and the need for fine needle aspiration puncture.
METHODS
Four endocrinologists from the same center blindly evaluated 100 ultrasound images of thyroid nodules from 100 different patients. The following ultrasound features were evaluated: composition, echogenicity, margins, calcifications, and microcalcifications. Nodules were also classified according to ATA, EU-TIRADS, K-TIRADS, and ACR-TIRADS classifications. Krippendorff's alpha test was used to assess interobserver agreement.
RESULTS
The interobserver agreement for ultrasound features was: Krippendorff's coefficient 0.80 (0.71-0.89) for composition, 0.59 (0.47-0.72) for echogenicity, 0.73 (0.57-0.88) for margins, 0.55 (0.40-0.69) for calcifications, and 0.50 (0.34-0.67) for microcalcifications. The concordance for the classification systems was 0.7 (0.61-0.80) for ATA, 0.63 (0.54-0.73) for EU-TIRADS, 0.64 (0.55-0.73) for K-TIRADS, and 0.68 (0.60-0.77) for K-TIRADS. The concordance in the indication of fine needle aspiration puncture (FNA) was 0.86 (0.71-1), 0.80 (0.71-0.88), 0.77 0.67-0.87), and 0.73 (0.64-0.83) for systems previously described respectively.
CONCLUSIONS
Interobserver agreement was acceptable for the identification of nodules requiring cytologic study using various classification systems. However, limited concordance was observed in risk stratification and many ultrasonographic characteristics of the nodules.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.