MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2014.03.009

Медицинская библиотека · JACC. Cardiovascular interventions · 2014

Impact of balloon post-dilation on clinical outcomes after transcatheter aortic valve replacement with the self-expanding CoreValve prosthesis.

Barbanti Marco, Petronio Anna Sonia, Capodanno Davide, Ettori Federica, Colombo Antonio, Bedogni Francesco, De Marco Federico, De Carlo Marco, Fiorina Claudia, Latib Azeem, Testa Luca, Bruschi Giuseppe, Poli Arnaldo, Giannini Cristina, Curello Salvatore, Maffeo Diego, Sgroi Carmelo, Martina Paola, Gulino Simona, Patanè Martina, Ohno Yohei, Attizzani Guilherme F, Immè Sebastiano, Cannata Stefano, Gentili Alessandra, Rossi Agnese, Tamburino Corrado

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to assess the incidence and clinical impact of balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR) with the CoreValve prosthesis (Medtronic Inc., Minneapolis, Minnesota).

BACKGROUND

BPD is a widely adopted strategy to reduce the degree of paraprosthetic regurgitation in case of transcatheter heart valve underexpansion. However, controversies still remain regarding its real effectiveness and safety.

METHODS

The ClinicalService (a nation-based data repository and medical care project) dataset was analyzed. All patients were dichotomized according to the need for BPD during the index procedure.

RESULTS

Among 1,376 patients, BPD of the transcatheter heart valve was performed in 272 (19.8%). In 37% of cases, it was unsuccessful at reducing the paravalvular regurgitation to mild or less. No case of valve embolization, new intravalvular regurgitation, coronary occlusion, and aortic root injury occurred during BPD. There were no statistically significant differences between the 2 groups in the incidence of in-hospital all-cause and cardiovascular mortality, neurological events, myocardial infarction, bleeding, conversion to open-chest surgery, and the need for a permanent pacemaker. The need for BPD did not emerge as an independent risk factor for all-cause (adjusted hazard ratio [HR]: 1.33, 95% confidence interval [CI]: 0.81 to 2.19, p = 0.264) and cardiovascular (adjusted HR: 1.48, 95% CI: 0.74 to 2.97, p = 0.265) mortality at 1 year after the procedure. In addition, BPD did not predispose to higher odds of neurological events during 12 months after TAVR (HR: 0.92, 95% CI: 0.45 to 1.88, p = 0.815).

CONCLUSIONS

This large study showed that BPD after TAVR was safe and not associated with increased rates of cerebrovascular events, mortality, myocardial infarction, and aortic root injury.

Для цитирования: Barbanti Marco, Petronio Anna Sonia, Capodanno Davide, Ettori Federica, Colombo Antonio, Bedogni Francesco, De Marco Federico, De Carlo Marco, Fiorina Claudia, Latib Azeem, Testa Luca, Bruschi Giuseppe, Poli Arnaldo, Giannini Cristina, Curello Salvatore, Maffeo Diego, Sgroi Carmelo, Martina Paola, Gulino Simona, Patanè Martina, Ohno Yohei, Attizzani Guilherme F, Immè Sebastiano, Cannata Stefano, Gentili Alessandra, Rossi Agnese, Tamburino Corrado. Impact of balloon post-dilation on clinical outcomes after transcatheter aortic valve replacement with the self-expanding CoreValve prosthesis.. JACC. Cardiovascular interventions. 2014. DOI: 10.1016/j.jcin.2014.03.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.