A SARS-CoV-2 and influenza rapid antigen test-based hospital isolation policy awaiting RT-PCR, a prospective observational study.
Аннотация
OBJECTIVES
This study aimed to evaluate the clinical performance of a combined SARS-CoV-2/influenza rapid antigen test (SIRAT) and to evaluate a SIRAT-based hospital isolation policy awaiting RT-PCR results for patients presenting at the emergency department (ED).
METHODS
We performed a prospective observational study including all adult patients presenting with influenza-like symptoms at the ED of two hospitals from 31 October 2022 to 31 March 2023. A SIRAT and SARS-CoV-2 and influenza RT-PCR were performed on upper respiratory samples. SIRAT results were compared with RT-PCR. Droplet and contact isolation measures (DCIM) were imposed based on SIRAT results awaiting RT-PCR. We monitored symptomatic nosocomial SARS-CoV-2 and influenza infections potentially caused by delayed isolation of patients with false negative SIRAT and the hours of unnecessary DCIM saved.
RESULTS
We included 1740 patients of whom 1296 were hospitalized. SARS-CoV-2 and influenza A/B prevalence were 12.7% (221/1740) and 9.9% (171/1740). Sensitivity and specificity of the SIRAT were 67.7% (95% CI 61.1-73.9%) (149/220) and 99.4% (95% CI 99.0-99.8%) (1510/1518) for SARS-CoV-2 and 52.7% (95% CI 44.9-60.4%) (89/169) and 99.1% (95% CI 98.5-99.5%) (1530/1544) for influenza A/B. We found a 0% nosocomial transmission risk for SARS-CoV-2 (95% CI 0-8.8%) and influenza (95% CI 0-10%). In all, 8712 hours in total or a median up to 6 hours 59 minutes (IQR (interquartile range) 11h03) per patient of unnecessary DCIM were saved.
DISCUSSION: A SIRAT-guided hospital isolation policy awaiting RT-PCR results for patients who present at the ED can save unnecessary isolation hours without having to lead to significant symptomatic nosocomial transmission of SARS-CoV-2 or influenza viruses.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.