MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsnano.3c07707

Медицинская библиотека · ACS nano · 2023

Graphene Field Effect Biosensor for Concurrent and Specific Detection of SARS-CoV-2 and Influenza.

Kumar Neelotpala, Towers Dalton, Myers Samantha, Galvin Cooper, Kireev Dmitry, Ellington Andrew D, Akinwande Deji

СтатьяПоддержка правительства СШАПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The SARS-CoV-2 pandemic has highlighted the need for devices capable of carrying out rapid differential detection of viruses that may manifest similar physiological symptoms yet demand tailored treatment plans. Seasonal influenza may be exacerbated by COVID-19 infections, increasing the burden on healthcare systems. In this work, we demonstrate a technology based on liquid-gated graphene field-effect transistors (GFETs), for rapid and ultraprecise sensing and differentiation of influenza and SARS-CoV-2 surface protein. Most distinctively, the device consists of 4 onboard GFETs arranged in a quadruple architecture, where each quarter is functionalized individually (with either antibodies or chemically passivated control) but measured jointly. The sensor platform was tested against a range of concentrations of viral surface proteins from both viruses with the lowest tested and detected concentration at ∼50 ag/mL, or 88 zM for COVID-19 and 227 zM for Flu, which is 5-fold lower than the values reported previously on a similar platform. Unlike the classic real-time polymerase chain reaction test, which has a turnaround time of a few hours, the graphene technology presents an ultrafast response time of ∼10 s even in complex and clinically relevant media such as saliva. Thus, we have developed a multianalyte, highly sensitive, and fault-tolerant technology for rapid diagnostic of contemporary, emerging, and future pandemics.

Для цитирования: Kumar Neelotpala, Towers Dalton, Myers Samantha, Galvin Cooper, Kireev Dmitry, Ellington Andrew D, Akinwande Deji. Graphene Field Effect Biosensor for Concurrent and Specific Detection of SARS-CoV-2 and Influenza.. ACS nano. 2023. DOI: 10.1021/acsnano.3c07707.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.