MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/01676831003660697

Медицинская библиотека · Orbit (Amsterdam, Netherlands) · 2010

Watery eye following patent external DCR: an MR dacryocystography study.

Detorakis Efstathios T, Drakonaki Eleni, Papadaki Efrosini, Pallikaris Ioannis G, Tsilimbaris Miltiadis K

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To examine patients with persistent watery epiphora following patent external dacryocystorhinostomy (DCR) with magnetic resonance imaging dacryocystography (MR-DCG).

METHODS

Patients with unobstructed nasolacrimal irrigation following external DCR were included. Five patients with watery epiphora constituted the study group (SG). Five patients without epiphora constituted the control group (CG). All patients underwent MR-DCG following the instillation of artificial tears in the conjunctival fornix. The osteotomy site was identified in T1-weighted coronal images. Lacrimal flow was assessed with modified T2-weighted (True Fast Imaging Steady State Pulse, "TrueFISP") coronal images before and 10 min after repeated blinking. Signal intensities at three regions of interest (ROIs), corresponding to the eyeball (ROI-1), conjunctival sac (ROI-2), and anastomotic site (ROI-3) were measured.

RESULTS

Differences in the diameter of both osseous and soft tissue ostia between SG and CG were statistically not significant. A post-blink increase in signal intensity at ROI-3 was noted in both groups, whereas differences in signal intensity for ROI-1 and ROI-2 were statistically not significant. The post-blink signal intensity increase in ROI-3 was significantly more pronounced in the CG, compared with the SG.

CONCLUSIONS

The fact that signal intensity increase at ROI-3 was less pronounced in the SG, compared with CG, implies a compromised "lacrimal pump" mechanism in the former group. The methodology presented may be used for the evaluation of post-DCR epiphora.

Для цитирования: Detorakis Efstathios T, Drakonaki Eleni, Papadaki Efrosini, Pallikaris Ioannis G, Tsilimbaris Miltiadis K. Watery eye following patent external DCR: an MR dacryocystography study.. Orbit (Amsterdam, Netherlands). 2010. DOI: 10.3109/01676831003660697.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.