DOI 10.1097/spv.0000000000000452
Polypropylene Mesh Predicts Mesh/Suture Exposure After Sacrocolpopexy Independent of Known Risk Factors: A Retrospective Case-Control Study.
Аннотация
OBJECTIVE(S): The aim of this study was to determine if ultralightweight polypropylene mesh reduced the risk of mesh/suture exposure after sacrocolpopexy compared with heavier-weighted polypropylene.
METHODS
Bivariate and multivariate analyses were used to interpret data from 133 cases and 261 control subjects to evaluate independent predictors of mesh/suture exposure after sacrocolpopexy from 2003 to 2013.
RESULTS
Multivariate logistic regression revealed that prior surgery for incontinence (odds ratio [OR], 2.87; 95% confidence interval [CI], 1.19-6.96), porcine acellular cross-linked collagen matrix with medium-weight polypropylene mesh (OR, 4.95; 95% CI, 1.70-14.42), other polypropylene mesh (OR, 6.73; 95% CI, 1.12-40.63), nonabsorbable braided suture for vaginal mesh attachment (OR, 4.52; 95% CI, 1.53-15.37), and immediate perioperative complications (OR, 3.64; 95% CI, 1.53-13.37) were independent risk factors for mesh/suture exposure. After multivariate analysis, ultralightweight polypropylene mesh was no longer associated with decreased rates of mesh/suture exposure after controlling for known risk factors identified during bivariate analysis (P = 0.423).
CONCLUSIONS
Both mesh choice and suture selection remained independent predictors of mesh/suture exposure, with heavier meshes increasing and monofilament suture decreasing rates of mesh/suture exposure. Based on this study, surgeons may consider use of delayed-absorbable, monofilament suture over nonabsorbable braided suture for attachment of vaginal mesh to reduce the risk of mesh/suture exposure when using mesh.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.