A clinical and cost-effectiveness analysis of the HeartMate 3 left ventricular assist device for transplant-ineligible patients: A United Kingdom perspective.

Lim Hoong Sern, Shaw Steven, Carter Alexander W, Jayawardana Sahan, Mossialos Elias, Mehra Mandeep R

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The clinical and cost-effectiveness of left ventricular assist device (LVAD) therapy for patients with advanced heart failure (HF) who are ineligible for heart transplantation is debated in the UK. This study develops an indirect comparison between the fully magnetically levitated HeartMate 3 (HM 3) LVAD and medical therapy (MT) to evaluate expected clinical and cost-effectiveness in the UK National Health Service (NHS) context.

METHODS

We performed an economic analysis comparing the HM3 pump against the HeartMate II LVAD (MOMENTUM 3), and then another analysis comparing MT with the first- and second-generation HeartMate XVE pump LVAD and HeartMate II LVAD for the same patient population (REMATCH and ROADMAP, respectively). By bridging those 2 analyses, an indirect comparison between HM3 and MT in the form of a network meta-analysis was developed. A literature search was performed to select the most appropriate pair of studies for this purpose. Outcomes were adjusted to produce Kaplan-Meier curves for the cost-effectiveness evaluation by using a decision-analytic model. Data were extrapolated linearly over a 5-year time horizon. Uncertainty and additional scenarios were addressed by one-way and probabilistic sensitivity analysis. Local costs and health utility were used from England, thereby representing the UK context.

RESULTS

The incremental cost-effectiveness ratio (ICER) for LVAD vs MT in transplant ineligible patients with advanced HF was estimated to be £47,361 per quality-adjusted life year gained, with a 97.1% probability of being cost-effective at £50,000. In a subgroup of patients who are inotropic therapy dependent (INTERMACS 1-3 severity profile), the ICER was £45,616, while for a population with less-ill ambulatory HF (INTERMACS profile 4-7) the ICER changed to £64,051.

CONCLUSIONS

This study provides evidence that HM3 LVAD therapy in advanced HF patients ineligible for heart transplantation may be cost-effective compared to MT in the NHS UK-England context. The ICER is lowest for patients dependent on inotropic support, but exceeds the willingness to pay threshold of £50,000 in ambulatory noninotropic therapy dependent advanced HF patients.

Для цитирования: Lim Hoong Sern, Shaw Steven, Carter Alexander W, Jayawardana Sahan, Mossialos Elias, Mehra Mandeep R. A clinical and cost-effectiveness analysis of the HeartMate 3 left ventricular assist device for transplant-ineligible patients: A United Kingdom perspective.. The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 2021. DOI: 10.1016/j.healun.2021.11.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.