MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2020.09.009

Медицинская библиотека · Heart rhythm · 2020

Effects of subcutaneous nerve stimulation with blindly inserted electrodes on ventricular rate control in a canine model of persistent atrial fibrillation.

Kusayama Takashi, Wan Juyi, Yuan Yuan, Liu Xiao, Li Xiaochun, Shen Changyu, Fishbein Michael C, Everett Thomas H, Chen Peng-Sheng

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Subcutaneous nerve stimulation (ScNS) delivered directly to large subcutaneous nerves can be either antiarrhythmic or proarrhythmic, depending on the stimulus output.

OBJECTIVE

The purpose of this study was to perform a prospective randomized study in a canine model of persistent AF to test the hypothesis that high-output ScNS using blindly inserted subcutaneous electrodes can reduce ventricular rate (VR) during persistent atrial fibrillation (AF) whereas low-output ScNS would have opposite effects.

METHODS

We prospectively randomized 16 male and 15 female dogs with sustained AF (>48 hours) induced by rapid atrial pacing into 3 groups (sham, 0.25 mA, 3.5 mA) for 4 weeks of ScNS (10 Hz, alternating 20-seconds ON and 60-seconds OFF).

RESULTS

ScNS at 3.5 mA, but not 0.25 mA or sham, significantly reduced VR and stellate ganglion nerve activity (SGNA), leading to improvement of left ventricular ejection fraction (LVEF). No differences were found between the 0.25-mA and sham groups. Histologic studies showed a significant reduction of bilateral atrial fibrosis in the 3.5-mA group compared with sham controls. Only 3.5-mA ScNS had significant fibrosis in bilateral stellate ganglions. The growth-associated protein 43 (GAP43) staining of stellate ganglions indicated the suppression of GAP43 protein expression in the 3.5-mA group. There were no significant differences of nerve sprouting among all groups. There was no interaction between sex and ScNS effects on reduction of VR and SGNA, LVEF improvement, or results of histologic studies.

CONCLUSION

We conclude that 3.5-mA ScNS with blindly inserted electrodes can improve VR control, reduce atrial fibrosis, and partially improve LVEF in a canine model of persistent AF.

Для цитирования: Kusayama Takashi, Wan Juyi, Yuan Yuan, Liu Xiao, Li Xiaochun, Shen Changyu, Fishbein Michael C, Everett Thomas H, Chen Peng-Sheng. Effects of subcutaneous nerve stimulation with blindly inserted electrodes on ventricular rate control in a canine model of persistent atrial fibrillation.. Heart rhythm. 2020. DOI: 10.1016/j.hrthm.2020.09.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.