DOI 10.1016/j.jelectrocard.2019.12.005

Медицинская библиотека · Journal of electrocardiology · 2019

Voltage dependent conduction abnormalities in His bundle pacing in patients without His Purkinje system disease.

Mahmud Rehan, Jamal Shakeel, Musheinesh Mohamed

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

During His bundle (HB) pacing, the active fixation of HB lead may cause disruption of the enclosed conduction fibers and cause conduction delay. His Purkinje conduction delays have been shown to revert to normal with higher voltage pacing.

OBJECTIVE

To determine if conduction delays seen with penetrative HB pacing are voltage dependent and can resolve with higher stimulus voltage.

METHODS

In 17 patients undergoing HBP, the effect of voltage on a composite His Purkinje system-ventricular activation time (hVAT) as well as electrocardiographic (ECG) evidence of conduction delay, was systematically evaluated.

RESULTS

There was highly significant prolongation of hVAT indicative of conduction delay in 13/17 patients. ECG changes of rightward delay were also seen in 9/13 patients. Both types of delays we manifest at lower voltages and we uniquely resolved by higher stimulation voltage. A pre-excitation like abnormality was also seen in 15/17 patients. This conduction abnormality was manifest at higher voltage without prolongation of hVAT. In 6/15 patients the pre-excitation like abnormality ceased at lower voltage.

CONCLUSION

HB pacing is associated with evidence of significant conduction delay noted at low voltage, which resolves with higher stimulation voltage. The more common pre-excitation like abnormality appears to occur at high voltage and, in of itself, does not appear to prolong hVAT.

Для цитирования: Mahmud Rehan, Jamal Shakeel, Musheinesh Mohamed. Voltage dependent conduction abnormalities in His bundle pacing in patients without His Purkinje system disease.. Journal of electrocardiology. 2019. DOI: 10.1016/j.jelectrocard.2019.12.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.