MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/11206721231221588

Медицинская библиотека · European journal of ophthalmology · 2023

Comparison of optical aberrations in keratoconus with scleral versus rigid gas permeable lenses.

Knoeri Juliette, Mhenni Rania, Friquet Chloé, Hage Alexandre, Cuyaubère Roxane, Borderie Marie, Leveziel Loïc, Bouheraoua Nacim, Borderie Vincent

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: to assess optical aberrations under scleral (SL) versus rigid gas permeable (RGP) lenses in patients with keratoconus.

METHODS

A prospective study including 25 eyes of 14 patients. The best-corrected visual acuity (BCVA) with corrective glasses, RGP and SL, stage of keratoconus (Amsler-Krumeich classification), minimum pachymetry, maximum keratometry, and corneal higher-order aberrations (i.e, total HOAs, coma, and trefoil) with RGP and with SL were collected. Aberrometry was performed using iTrace® aberrometer (Tracey Technologies, USA).

RESULTS

80% of the included keratoconus patients were stage 4, with a mean age of 34.3 years (±8.8). There were no significant differences in mean BCVA (logMAR) between SL and RGP. The mean BCVAs were significantly better both with SL (p < 0.0001) and RGP (p < 0.0001) compared with corrective glasses. Total HOAs (p = 0.01), coma (p = 0.003) and trefoil (p = 0.008) were significantly lower with SL compared with RGP. The BCVA decreased with the stage of keratoconus in SL (p = 0.01) and RGP (p = 0.02). The BCVA decreased with decreasing minimum pachymetry in SL (p = 0.02) and RGP (p = 0.002), and with increasing maximum keratometry in SL (p = 0.02) and RGP (p = 0.01). Significant correlations were found between BCVA, total HOAs (p = 0.008), and coma (p = 0.02) in SL.

CONCLUSION

For the same keratoconus patients, total higher order, coma and trefoil optical aberrations were reduced with scleral lenses compared to rigid gas permeable lenses.

Для цитирования: Knoeri Juliette, Mhenni Rania, Friquet Chloé, Hage Alexandre, Cuyaubère Roxane, Borderie Marie, Leveziel Loïc, Bouheraoua Nacim, Borderie Vincent. Comparison of optical aberrations in keratoconus with scleral versus rigid gas permeable lenses.. European journal of ophthalmology. 2023. DOI: 10.1177/11206721231221588.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.