MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/bioengineering10111335

Медицинская библиотека · Bioengineering (Basel, Switzerland) · 2023

Diagnostic Validation of the Screening Corneal Objective Risk of Ectasia Analyzer Evaluated by Swept Source Optical Coherence Tomography for Keratoconus in an Asian Population.

Kim Kookyoung, Koh Kyungmin, Lee Seongjun, Lee Yongwoo

СтатьяПеревод пока не подготовлен

Аннотация

We aimed to investigate the diagnostic accuracy of Screening Corneal Objective Risk of Ectasia (SCORE) Analyzer software using ANTERION, a swept-source optical coherence tomography device, for keratoconus diagnosis in an Asian population. A total of 151 eyes of 151 patients were included in this retrospective study as follows: 60, 45, and 46 keratoconus, keratoconus suspects, and normal control eyes, respectively. Parameters in the SCORE calculation, including six indices, were compared for the three groups. The receiver operating characteristic curve analysis and cut-off value were estimated to assess the diagnostic ability to differentiate keratoconus and keratoconus suspect eyes from the normal group. The SCORE value and six indices were significantly correlated-"AntK max" (R = 0.864), "AntK oppoK" (R = 0.866), "Ant inf supK" (R = 0.943), "Ant irre 3mm" (R = 0.741), "post elevation at the thinnest point" (R = 0.943), and "minimum corneal thickness" (R = -0.750). The SCORE value showed high explanatory power (98.1%), sensitivity of 81.9%, and specificity of 78.3% (cut-off value: 0.25) in diagnosing normal eyes from the keratoconus suspect and keratoconus eyes. The SCORE Analyzer was found to be valid and consistent, showing good sensitivity and specificity for keratoconus detection in an Asian population.

Для цитирования: Kim Kookyoung, Koh Kyungmin, Lee Seongjun, Lee Yongwoo. Diagnostic Validation of the Screening Corneal Objective Risk of Ectasia Analyzer Evaluated by Swept Source Optical Coherence Tomography for Keratoconus in an Asian Population.. Bioengineering (Basel, Switzerland). 2023. DOI: 10.3390/bioengineering10111335.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.