MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijo.ijo_1988_23

Медицинская библиотека · Indian journal of ophthalmology · 2023

Customized corneal allogenic intrastromal ring segments (CAIRS) for keratoconus with decentered asymmetric cone.

Jacob Soosan, Agarwal Amar, Awwad Shady T, Mazzotta Cosimo, Parashar Parnika, Jambulingam Sambath

СтатьяПеревод пока не подготовлен

Аннотация

Corneal allogenic intrastromal ring segments (CAIRS) refer to the intracorneal placement of fresh, unprocessed, processed, preserved, or packaged allogenic rings/segments of any type/length. We described uniform-thickness CAIRS previously. We now describe a new technique of customized CAIRS to personalize the flattening effect as per individual topography. A prospective interventional case series of patients with pericentral/ paracentral decentered cones and gradation of keratometry with one side steeper than the other was conducted. Individually customized tapered CAIRS with variable volume, arc length, taper length, and gradient of taper were implanted. In total, 32 eyes of 29 patients with at least 1-year follow-up were included. Special double-bladed trephines and a CAIRS customizer template allowed the creation of individually customized CAIRS. Mean uncorrected distance visual acuity (UDVA) and spectacle-corrected distance visual acuity improved from 0.22 to 0.47 (P = 0.000) and from 0.76 to 0.89 (P = 0.001), respectively. Significant improvement was seen in K1, K2, Km, Kmax, topographic astigmatism, Q-value, sphere, cylinder, spherical equivalent, Root Mean Square (RMS), Higher Order Aberrations (HOA), and vertical coma (P < 0.01, 0.05). There was no significant change in the width or height of CAIRS between 1 month and last visit on anterior-segment optical coherence tomography. Five eyes continued to remain at the same UDVA, 27 eyes had at least 2 lines, and 13 eyes had at least 3 or more lines improvement in UDVA. The maximum improvement in UDVA was 7 lines. A significant difference in flattening was obtained at different zones across the tapered CAIRS. Thus, differential flattening was achieved across the cone based on the customization plan. Personalized customization was possible for each cornea, unlike limited models of progressive-thickness synthetic segments. Allogenic nature, greater customizability, efficacy, and absent need for large inventories are advantages compared to synthetic segments.

Для цитирования: Jacob Soosan, Agarwal Amar, Awwad Shady T, Mazzotta Cosimo, Parashar Parnika, Jambulingam Sambath. Customized corneal allogenic intrastromal ring segments (CAIRS) for keratoconus with decentered asymmetric cone.. Indian journal of ophthalmology. 2023. DOI: 10.4103/ijo.ijo_1988_23.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.