Implantation of Intracorneal Ring Segments in Keratectasia: Effects on Corneal Biomechanics in 112 Eyes.

Hamon Loïc, Pfahl Luisa J, Flockerzi Elias, Berger Tim, Langenbucher Achim, Seitz Berthold, Daas Loay

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this study was to analyze changes in corneal biomechanical properties after implantation of intracorneal ring segments (ICRSs) in keratectasia.

METHODS

This retrospective single-center study included 112 patient eyes that underwent femtosecond laser-assisted ICRS implantation (Intacs SK; Addition Technology Inc, Des Plaines, IL) for keratectasia. Biomechanical analysis was performed using the Ocular Response Analyzer (ORA; Reichert Inc, Depew, NY), with determination of corneal resistance factor, corneal hysteresis, and Keratoconus Match Index, as well as by Corvis ST (OCULUS, Wetzlar, Germany), with determination of stiffness parameter A1, Ambrosio relational thickness to the horizontal profile (Arth), integrated radius, deformation amplitude ratio, and stress-strain index as well as Corvis Biomechanical Index and Tomographic Biomechanical Index. Data collection was performed preoperatively and 6 months postoperatively for ORA and Corvis ST and additionally after 1 and 2 years for ORA.

RESULTS

The corneal resistance factor decreased significantly postoperatively (5.8 ± 1.7 mm Hg) compared with preoperatively (6.75 ± 3.7 mm Hg; P = 0.021) and increased again during follow-up (6.2 ± 1.9 mm Hg; P = 0.024), without regaining preoperative values. Corneal hysteresis and Keratoconus Match Index did not change significantly. Stiffness parameter A1 ( P = 0.045) increased significantly after ICRS implantation and Arth decreased significantly from 181 ± 85 to 150 ± 92 ( P = 0.016). However, there was no significant postoperative change for others Corvis parameters.

CONCLUSIONS

Corneal biomechanical properties showed inconsistent changes after ICRS implantation. Classical corneal biomechanical parameters (using single central air-puff tonometers) do not seem to be suitable for follow-up after ICRS implantation.

Для цитирования: Hamon Loïc, Pfahl Luisa J, Flockerzi Elias, Berger Tim, Langenbucher Achim, Seitz Berthold, Daas Loay. Implantation of Intracorneal Ring Segments in Keratectasia: Effects on Corneal Biomechanics in 112 Eyes.. Cornea. 2023. DOI: 10.1097/ico.0000000000003419.