MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-023-06250-7

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2023

Enhanced morphological assessment based on interocular asymmetry analysis for keratoconus detection.

Dong Ruilan, Liu Yan, Zhang Yu, Chen Yueguo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To clarify the interocular asymmetry of corneal morphological descriptors and evaluate its discriminant ability of keratoconus (KC).

METHODS

This retrospective study recruited 344 normal participants and 290 KC patients, randomized to training and validation datasets. Interocular correlation and agreement were evaluated on 44 corneal morphological descriptors derived from Schiempflug tomography. Logistic regression models were constructed using binocular data and of which diagnostic performance was evaluated using the area under receiver operating characteristics curve (AUC), net reclassification improvement (NRI), and integrated discrimination improvement (IDI).

RESULTS

Interocular agreement of corneal descriptors is better in the normal than in KC except for dimensions of cornea and anterior chamber. The interocular asymmetry increases along with the severity of KC. Interocular asymmetry in maximum anterior keratometry, mean anterior keratometry and higher-order aberrations of anterior surface show high AUC above 0.950. Binocular logistic regression index reaches an AUC of 0.963 with high specificity (95.2%) and brings gain to monocular parameters in distinguishing the normal eyes from KC (NRI = 0.080 (0.042 ~ 0.118), P < 0.001) and IDI = 0.071 (0.049 ~ 0.092), P < 0.001). Interocular asymmetry benefits even more in subclinical keratoconus (SKC) detection reflected by NRI (0.4784 (0.2703-0.6865), P < 0.001) and IDI (0.2680 (0.1495-0.3866), P < 0.001) measures.

CONCLUSION

Interocular asymmetry is a well-characterized feature of KC and related to the severity. It is feasible to apply the interocular asymmetry in diagnosis of KC and SKC as a replenishment of monocular parameters and in progression tracking.

Для цитирования: Dong Ruilan, Liu Yan, Zhang Yu, Chen Yueguo. Enhanced morphological assessment based on interocular asymmetry analysis for keratoconus detection.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2023. DOI: 10.1007/s00417-023-06250-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.