MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/j.jcrs.0000000000001275

Медицинская библиотека · Journal of cataract and refractive surgery · 2023

Discrimination between keratoconus, forme fruste keratoconus, and normal eyes using a novel OCT-based tomographer.

Saad Alain, Debellemanière Guillaume, Zeboulon Pierre, Rizk Maria, Rouger Hélène, Mazharian Adrien, Grise-Dulac Alice, Panthier Christophe, Gatinel Damien

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To combine objective machine-derived corneal parameters obtained with new swept-source optical coherence tomography (SS-OCT) tomographer (Anterion) to differentiate between normal (N), keratoconus (KC) and forme fruste KC (FFKC).

SETTING

Laser Center, Hôpital Fondation Adolphe de Rothschild, Paris, France.

DESIGN

Retrospective study.

METHODS

281 eyes of 281 patients were included and divided into 3 groups: N (n = 156), FFKC (n = 43), and KC (n = 82). Eyes were included in each group based on objective evaluation using Nidek Corneal Navigator, and subjective evaluation by authors. The SS-OCT system provided anterior and posterior corneal surface and pachymetry derived variables. The training set was composed of 143 eyes (95 N, 43 FFKC). Discriminant analysis was used to determine the group of an observation based on a set of variables. The obtained formula was tested in the validation set composed of 61 N and 82 KC.

RESULTS

Among curvature parameters, the FFKC had significantly higher irregularity index at 3 mm and 5 mm, higher inferior-superior index, higher SteepK-OppositeK index and inferiorly decentered posterior steepest keratometry. Among thickness parameters: central pachymetry, thinnest pachymetry, percentage of thickness increase from center to periphery, and inferior decentration of the thinnest point were statistically different between groups. Combination of multiple variables into a discriminant function (F1) included 5 parameters and reached an area under the receiver operating characteristic curve (AUROC) of 0.95 (sensitivity = 75%, specificity = 98.5%) for detection of FFKC. F1 differentiates N from KC with AUROC = 0.99 (sensitivity = 99%, specificity = 99%).

CONCLUSIONS

Combining anterior and posterior curvatures variables along with pachymetric data obtained from SS-OCT allowed automated detection of early KC and KC with very good accuracy (87% and 99.5% respectively).

Для цитирования: Saad Alain, Debellemanière Guillaume, Zeboulon Pierre, Rizk Maria, Rouger Hélène, Mazharian Adrien, Grise-Dulac Alice, Panthier Christophe, Gatinel Damien. Discrimination between keratoconus, forme fruste keratoconus, and normal eyes using a novel OCT-based tomographer.. Journal of cataract and refractive surgery. 2023. DOI: 10.1097/j.jcrs.0000000000001275.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.